Original source · versioned page text
25-0424 Structural Issue A(1)(1)
Provide 50x80x3.0 Fabricated Unequal Angle
(Alloy & Temper - 6060/T5 or 6106/T6)
DJ1 with 2/No.14 x 20mm SS tek screw each way
BR1
80
BR1
Neoprene washers between
all SS fixings and aluminium.
Provide 2/No.14 x 20mm SS tek screw each
connection with Neoprene washers between
400 all SS fixings and aluminium.
1 6mm end plates CFW all round and to BR1
Typ ST
1 ST
10mm end plates
6mm CFW
1 Typical.
1
1/M16 - SS316
C1
threaded rod through Refer to S03
C1 for reinforcement details
BR1
125x50x6.0mm UA
4mm CFW to BR1
2/M12 SS Grade 316
chemset anchors.
200mm min embedment.
High strength shrinkage
Epoxy = REO 502
compensated grout pad
C1 below
SJ1
BR1
Stitch weld 'C' Section together Provide 50x80x3.0 Fabricated Unequal Angle
Neoprene washers between (Alloy & Temper - 6060/T5 or 6106/T6)
all SS fixings and aluminum. with 2/No.14 x 20mm SS tek screw each way
BR1
80
BR1
SJ1 SJ1
C1
315mm Ø
Issue Made By Date Description PROPOSED NEW JETTY Scale : 1:100 NOTES:
A WPH 05/09/25 Issue for construction
at LOT 444 (#18) THE PENINSULA, NOOSAVILLE
REVISION
Job No.: 25-0424 1. Do not scale drawings.
2. Scale is correct at A3.
BUILDER: PONTOON WORKS
Dwg No.: S05 3. Check and verify all dimensions
Designed By : J. SAYERS BEng (Civil) Hons Drawn By : WPH Date : 05/09/25 prior to commencement of work.
Certified By : B.R. CROMAR BEng (Civil) MIEAust CPEng RPEQ NER Date : 05/09/25 Ph: (07) 5444 5578 Email: [email protected] CONNECTION DETAILS
See the original
The page text is free to read. Viewing or downloading an original file needs an account.