NETANYA RESORT - 75 HASTINGS STREET NOOSA MAIN BEACH. Peer Review Response - Architecture Project No. 19021 Date 4/8/2020 Hastings Street frontage 1. NR notes that in the proposal the palm trees currently existing on the western side of the driveway are to be removed - NR recommends that 1 or more of these palm trees be retained. Image 1 below indicates an established palm tree positioned within the central forecourt planter. Further investigation by the Landscape Architect will determine if an existing palm tree will be suitable for the transplant. As an alternative, the Landscape Architect has proposed a cluster of Archontophoenix Cunninghamiana’s, one cluster adjacent to the lift tower and another within the central planter. To add varied height and canopy to the central planter a Cupaniopsis Anacardioides (Tuckeroo) has also been suggested. The part Ground Floor Plan below indicates the proposed location of the Palms and Tuckeroo to the forecourt. Image 1 Hastings Street Frontage Central Driveway 2. NR would recommend placing an additional tree at the corner (in front of Bellissima Boutique) behind the curved timber seat. The Landscape Architect has proposed a Cupaniopsis Anacardioides (Tuckeroo), a smaller tree complementing the adjacent established trees. Image 2 and the part Ground Floor Plan below indicate the proposed location of the Tuckeroo in front of Bellissima Boutique. The image also includes the adjacent council path, landscaping and public amenities located to the south.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 6 pages
Page 2
Image 2 Hastings Street Frontage South West Corner 3. NR notes that a new surface finish is proposed to the existing forecourt in front of the building containing Massimo’s Gelataria. What is currently shown on the propose drawings is bland. Landscape architect input is required so that the floor finish can blend in with the existing surrounding footpath surface finishes. The image below indicates additional landscaping and outdoor seating to the commercial frontage. The existing planters have been extended in length adjacent to the deck stairs; the planter walls are stone faced with cantilever timber bench seating. The existing brick paved area replaced with Granite Grey tiles to match the existing path to the Netanya frontage. Image 3 Hastings Street Frontage South East Corner
Page 3
Hastings Street Part Ground Floor Plan Park Road frontage 4. NR suggests that the eastern wall of the proposed first floor ablutions block, facing Park Road, be painted a dark colour. Image 4 below indicates the upper level Linea horizontal weatherboard clad wall painted in a dark recessive colour. The windows are also reconfigured in a horizontal full width arrangement. A landscape trellis incorporated at ground provides screening to the existing electrical substation. Image 4 Park Road Frontage
Page 4
5. The timber trellis is currently proposed to stop short of the corner of the site – NR would recommend that the trellis continue to the corner of the site, so as to tidy up this corner and improve the aesthetics of the building façade at this location. Image 5 below indicates the proposed landscape trellis screen extending for the full length of the wall to the north east corner. A portion of the trellis screen incorporates a horizontal aluminum batten screen in front of the existing gas bottle enclosure; the remainder of the trellis screen fixed to the existing rendered blockwork boundary wall. The Landscape Architect has suggested a combination of native creepers; Cissus Antarctica, Fraser Island or Pandroea ‘Southern Belle’ with native ground cover or grass such as Dianella Caerulea and vertical plants such as Cordyline Glauca. The existing pockets of landscape adjacent to the property boundary and within the council pathway have been maintained in area. Image 5 Park Road Frontage North East Corner Beachside frontage 6. NR would recommend making the two middle pergolas different so as to break up the run of pergolas. Images 6 & 7 below indicate the preferred rooftop pergola detail; several options had been considered including changing the middle roof top pergolas to an angled profile replicating the poolside entry structure. Our client raised several concerns with the angled design, including unit owner acceptance and the visual effect on the overall character of the building. The horizontal arrangement of the aluminum pergola frame was ultimately adopted for simplicity in detail and to compliment the linear length of the northern elevation. The decision was taken to punctuate the expansive pergola structure with a distinct change of frame colour on the central pergola and the western pergolas. All other beachside frontage pergola frames have been changed to a lighter colour to appear to blend in with the background sky. Horizontal sunscreen battens extend over the pergola frames; open portions of the frame visually punctuate its linear length and delineate between the individual roof top terraces. The pergola frames adjoin the rooftop mechanical exhaust risers and are integral with the concealment of the existing roof top fan units. The pergola frames have been lowered in height by 300mm to reduce the overall scale and visual appearance. A clearance height of 2.4metres measured to the underside of the pergola frame will be adopted.
Page 5
Image 6 Beach Front Frontage North Elevation Image 7 Beach Front Frontage North West Corner Elevation 7. NR would recommend Council conditioning that no screens, walls, or solid roofs ever be installed on the roofscape and pergolas. A frameless glass balustrade is located to the roof top perimeter; the private roof terraces remain fully open in the orientation of their outlook. Existing rendered blockwork walls are centrally located between the private roof terraces and adjacent to the common area circulation walkway. The pergola frames are partially covered with aluminum batten screening, there are no solid roof elements over the private roof terraces.
Page 6
Central Courtyard 8. NR would prefer that only fire stair 01 be extended to the roof terrace level. (However, understands that doing so may not satisfy the building certifier’s travel distance requirements – and therefore understands if fire stair 02 needs to be extended) 9. NR would then question whether both stair 01 and stair 02 need to be extended, or whether, more preferably, the extension of just one staircase will achieve the necessary compliance. The vertical extension of the central stair 01 and the eastern stair 02 provide the required alternative escape paths from the roof top terraces in accordance with the National Construction Code D1.4 and D1.5. Stair 02 is required within 6 metres of the eastern private roof terrace gates. The centrally located Stair 01 is required as the travel distance between stair 02 and the existing stair 03 is greater than 45 metres. 10. NR would recommend that the bulk of the new roof planes over the extended staircase/s be minimised. Images 8 & 9 below indicate the revised stair 01 and 02 roof detailing. The roof area has been substantially reduced with its perimeter overhang slightly projecting beyond the extremity of the stair. The profile of the roof is simplified as two roof planes with a central ridge. The steeper roof angle over the stair reduces the overall scale and height; it also replicates the profile of the ground level commercial roof. The visual appearance of the roof when viewed from Hastings Street has been minimized, the horizontal fascia is the prominent roof element; the roof plane aligns with the perspective view. The openness of the aluminum screen to the perimeter of the stair provides transparency and a lightweight appearance when viewed from Hastings Street. The Linea weatherboard clad fin walls each side of the stair flights vertically connect the roof planes to the stair structure. Image 8 Hastings Street Frontage Elevated View
Page 7
Image 9 Hasting Street Frontage Stair & Lift View
11. NR notes that lift core 01 already provides a centralised point of access to the roof terrace, and questions why
lift core 02 needs to be extended to provide a second lift access. From a visual amenity standing, NR would
prefer that lift core 02 not be extended.
Currently the roof top terraces in Building B are accessed from the level 3 external unit entries via a non-compliant
spiral stair. As part of the building alterations, the existing spiral stairs will be removed; the extension of lift 02
provides exclusive roof access for the level 3 eastern units. In addition, lift 02 is generally used by the maintenance
and housekeeping staff; this will simplify access to all levels of the building separate from guests.