10/0811 - MCU - Multiple Dwelling Type 2 - Duplex [As Published] · 132010.811
20-22 TRISTANIA DRIVE; MARCUS BEACH Calculation of Design Discharges using Rational Method ARI 4 Year 2 Year 10 Year 20 Year 50 Year fi 50% 50% 50% 50% 50% Cro 08 08 os 08 o8 Fy 08 0.85 1 1.05 1.15 Cy 0.64 0.68 og C.84 0.92 tc (min) 6 min 6 min 6 min 86min 6 min ( (mm/hr) 116 148 204 232 269 A (Ha) 0.81 0.81 0.81 0.81 0.81 Q (m'ls 0.17 0.23 0.37 0.44 0.56 Capacity of 300 diamater pipe at 10% grade = 0.35 m3/s (Refer Chart attached) > QS (0.31m3/s} Therefore OK Capacity at Culvert entrance based on an allowable headwater depth of approximately 0.9m = 0.17m3/sec (Refer culvert chart attached) Therefore Remaining flow In 100 year storm event Is 0.64 - 0.17 = 0.47m3/s Calculation of Overland Flow Capacity down driveway using Mannings Equation Drainage Calcutations 23/04/20104:34 PM