Council archive · source document
10/0811 - MCU - Multiple Dwelling Type 2 - Duplex [As Published] · 132010.811
______ 20-22 TRISTANIA DRIVE, MARCUS BEACH
Calculation of Design Discharges using Rational Method
ARI 1 Year 2 Year 10 Year 20 Year 50 Year
4 50% 50% 50% 50% 50%
Cy 08 0.8 a8 08 08
Fy 08 0.85 4 1.05 116
cy 0.64 0.68 0.8 0.84 0.92
te (min) 8 min 6 min 6 min 6 min 6 min
{ (mmr) 116 148 204 232 269
A (Ha) 0.81 0.81 0.81 0.81 0.81
Qimis 0.17 0.23 0.37 0.44 0.56
Capacity of 300 diamater pipe at 10% grade = 0.35 m3/s (Refer Chart attached) > Q5 (0.31m3/s) Therefore OK
Capacity at Culvert entrance based on an allowable headwater depth of approximately 0.9m = 0.17m3/sec (Refer culvert chart attached)
Therefore Remalning flow in 100 year storm event Is 0.64 - 0.17 = 0.47m3/s
Calculation of Overland Flow.Capacity down driveway using Mannings Equation
[ ne
Crossfali
0,012
2%
LuwWes
Drainage Catcutations
23/04/20404:34 PM