10/0811 - MCU - Multiple Dwelling Type 2 - Duplex [As Published] · 132010.811
my fet aR GENERAL NOTES. 1. ALL WORK IS TO COMPLY WITH THE QUEENSLAND PLUMBING & DRAINAGE ACT 2002 AND LOCAL AUTHORITY REQUIREMENTS. 2. THESE DRAWINGS ARE DIAGRAMMATIC ONLY. USE DIMENSIONED BUILDING CONSTRUCTION PLANS FOR ANY SET OUT REQUIREMENTS. 3. OBTAIN APPROVALS FROM ALL AUTHORITIES HAVING JURISDICTION AND PAY ALL FEES DUE. 4. THE CONTRACTOR IS TO VISIT THE SITE TO BE FULLY AWARE OF EXISTING SERVICES AND SITE CONDITIONS PRIOR TO COMMENCEMENT OF WORK. ANY CLAIM FOR VARIATION ON THE BASIS OF LACK OF KNOWLEDGE WILL NOT BE ACCEPTED. 5. ENSURE INVERT LEVELS AND MINIMUM COVER IS ACHIEVABLE PRIOR TO COMMENCEMENT OF WORK ON SITE. 6. ALL PLUMBING AND DRAINAGE SERVICES THAT PENETRATE FIRE RATED WALLS AND FLOORS MUST BE INSTALLED TO COMPLY WITH THE REQUIRED FIRE RESISTANCE LEVEL. SANITARY NOTES 1. ‘ALL SANITARY AND TRADE WASTE PIPEWORK SHALL BE 100MMe AND BE INSTALLED AT 1:60 MINIMUM GRADE (UNO). 2. PROVIDE INSPECTION OPENINGS ON SANITARY DRAINAGE IN COMPLIANCE WITH AS/NZS 3500.2 3. AN OVERFLOW RELIEF GULLY SHALL BE INSTALLED ON EACH DRAIN CONNECTION TO SEWER AND EACH DRAIN ON AN UNSEWERED PROPERTY. 4. AN INSPECTION SHAFT TO BE INSTALLED AT OR NEAR THE POINT OF CONNECTION TO THE SEWER (UNO). STORMWATER NOTES 1. ALL STORMWATER DRAINAGE SHALL BE 100MM@ AND BE INSTALLED AT 1:100 MINIMUM GRADE (UNO). 2. DOWNPIPES TO HAVE MINIMUM CROSS SECTIONAL AREA EQUAL TO 100MM (UNO). 3. ROOF GUTTERS AND DOWNPIPES TO FULLY COMPLY WITH THE REQUIREMENTS OF AS/NZS3500.3. MATERIALS 1, WATER SERVICES -— TO AS/NZS 3500 2. SANITARY DRAINAGE — PVC CLASS DWV 3. SANITARY PLUMBING — PVC CLASS DW 4. DOWNPIPES -— PVC CLASS DWV(UNO) 5. STORMWATER UP TO 300MM@ — PVC CLASS SW HEAVY (UNO) 6. STORMWATER OVER 300MM@ — CONCRETE (RUBBER RING JOINT) CL3/FRC (SUPERTITE) CLASS 2 7. SUBSOIL DRAINAGE — 100MM@ PERFORATED PVC IN FILTER SOCK (UNO) 8. FIRE SERVICES ABOVE GROUND ONE STEEL "FIRE PLUS” MEDIUM 9. FIRE SERVICES BELOW GROUND PVC-M (BLUE RHINO) 10. TRADE WASTE INGROUND HDPE OR VITRIFIED CLAY 11. TRADE WASTE ABOVE GROUND HDPE OR POLYPROPYLENE WATER SERVICE NOTES 1. COLD WATER PIPEWORK TO BE A MINIMUM OF 15MM@ TO INDIVIDUAL OUTLETS/FIXTURES AND 20MM¢ OR GREATER TO MORE THAN ONE ABBREVIATIONS DP DOWNPIPE OUTLETS/FIXTURES (UNO). EJ EXPANSION JOINT FFL FINISHED FLOOR LEVEL qT . 2. 15MM@ COLD WATER PIPEWORK TO BE A MAXIMUM LENGTH OF 3METRES. PSL FINISHED SURFACE LEVEL 3. WATER SUPPLY PIPE SIZES INDICATED ON THESE DRAWINGS ARE EQUIVALENT los INSPECTION OPENING TO SURFACE TO TYPE "B” COPPER TUBE. IF USING AN ALTERNATIVE MATERIAL THE IL INVERT LEVEL INTERNAL DIAMETER OF THE PIPE SHALL BE EQUAL TO OR GREATER THAN sw STORMWATER THAT INDICATED ON THESE DRAWINGS. SL SURFACE LEVEL 4. HEATED WATER’ PIPEWORK SHALL BE 20MMé FROM THE HEATER TO SHOWER UNO UNLESS NOTES OTHER BRANCH THEN 15MM¢@ TO ALL OTHER OUTLETS/FIXTURES. 5. WATER HEATERS IN CEILING SPACE SHALL HAVE THE ISOLATING VALVES BELOW Development Counter CEILING. ~ 8 JUN 2010 6. WATER PIPEWORK TO BE INSTALLED IN WALL FRAMING AND ABOVE CEILING (NO) "> Tewanti 7. ALL HEATED WATER OUTLETS USED PRIMARILY FOR PERSONAL HYGIENE LEGE D in PURPOSES ARE TO BE TEMPERATURE CONTROLLED TO A MAXIMUM OF 50°C ~ - GENERALLY AND 45°C AT'DISABLED”ACCESS AREAS. SANITARY 8. HEATED WATER TO DISABLED ACCESS AREAS TO BE TEMPERATURE CONTROLLED SUBSOIL _—_— BY A THERMOSTATIC MIXING VALVE. STORMWATER —— oo EXIST SANITARY PLUMBING —— EXIST SEWER ———$ EXIST STORMWATER sw 20 & 22 TRISTANIA DRIVE A 20/05/10 CLIENT 18 NSSUE | DATE REVISION STATUS IDESIGNED} Plumbin eg eal Acar ian bradford conoultants pty itd . ian bradford + PIF - (07) 5448 3875 M - 0412654598 * PO BOX 334 PEREGIAN BEACH Q4573 E- [email protected] g consultants pty ltd BSA LICENCE NUMBER:- 1121367 LICENCE CLASS:- HYDRAULIC SERVICES DESIGN {including on site wastewater management) PROJECT STORMWATER DISPOSAL PROPOSED 4 UNIT DEVELOP. 20 & 22 TRISTANIA DRIVE MARCUS BEACH MENT TIME HYDRAULIC SERVICES ABBREVIATIONS LEGEND, NOTES, LOCALITY MAP, CUENT “ALTUM CONSTRUCTIONS] A3 SCALE NTS U.N.O. Dw No REV A 10031 - 1 SHEET 1 OF 2
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
10/0811 - MCU - Multiple Dwelling Type 2 - Duplex [As Published]Related documentApplication case desk ↗
About this file
- File size
- 4.7 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.