F orm 15—C o m plia n c e C ertific ate for b uildin g D e sig n or S p e cific atio n
NOTE This is to be used for the purposes of section 10 of the Building Act 1975 and/or section 46 of the
Building Regulation 2006.
RESTRICTION: A building certifier (class B) can only give a compliance certificate about whether
building work complies with the BCA or a provision of the QDC. A building certifier (Class B) can
not give a certificate regarding QDC boundary clearance and site cover provisions.
1. Property description Street address (include no., street, suburb / locality & postcode)
This section need only be completed if
details of street address and property No 61 Morinda Circuit, Noosaville.
description are applicable.
EG. In the case of (standard/generic) Postcode
pool design/shell manufacture and/or Lot & plan details (attach list if necessary)
patio and carport systems this section
may not be applicable.
The description must identify all land the
In which local government area is the land situated?
subject of the application. Noosa Shire Council
The lot & plan details (eg. SP / RP) are
shown on title documents or a rates notice.
If the plan is not registered by title, provide
previous lot and plan details.
2. Description of component/s certified
Clearly describe the extent of work covered by Structural design - Frame, Tie down & bracing.
this certificate, e.g. all structural aspects of the
steel roof beams.
3. Basis of certification
Detail the basis for giving the certificate and the AS 1170.1 SAA Loading Code.
extent to which tests, specifications, rules,
standards, codes of practice and other
AS1684.3 Residential timber framed construction.
publications, were relied upon. AS 3700 – Masonry in Buildings.
AS 4100 - Steel Structures.
4. Reference documentation
Clearly identify any relevant documentation, W6107 de
e.g. numbered structural engineering plans.
LOCAL GOVERNMENT USE ONLY
D ate re c eive d R efere n c e N u m b er/s
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 4 pages
Page 2
5. Building certifier reference number Building certifier reference number
6. Competent person details Name (in full)
A competent person for building work, means a
person who is assessed by the building certifier
for the work as competent to practise in an
Ray Williams.
aspect of the building and specification design, Company name (if applicable) Contact person
of the building work because of the individual’s
skill, experience and qualifications in the Sunrise Design Qld Pty Ltd. Ray
aspect. The competent person must also be
registered or licensed under a law applying in Phone no. business hours Mobile no. Fax no.
the State to practice the aspect. 5442 5930 5442 5934
If no relevant law requires the individual to be Email address
licensed or registered to be able to give the
help, the certifier must assess the individual as
having appropriate experience, qualifications or
skills to be able to give the help. Postal address
If the chief executive issues any guidelines for PO Box 621, Cooroy.
assessing a competent person, the building
certifier must use the guidelines when Postcode Q 4563
assessing the person.
Licence or registration number (if applicable)
RPEQ 2166
7. Signature of competent person Signature Date
This certificate must be signed by the individual September 27, 2016
assessed by the building certifier as competent.
The Building Act 1975 is administered by the
Department of Infrastructure and Planning
Department of Infrastructure and Planning
Page 3
Report No: W6107 de.
Client Name: K Grandemange
Report Date: September 27, 2016
Site Address: No 61 Morinda Circuit, Noosaville.
Structural Details.
Tie down
Connection Max kN Fixing – beams are to fixed Uplift Joint
Uplift force both ends value kN group
Trusses to top plate & na As per truss manufacturer’s na na
beams specifications.
Main roof [email protected] 30x0.8 GI strap with 4/2.8 mm 4.7 JD4
900mm centres max nails per face or fix with joist min
hangers 6 nails per face
Deck [email protected] 2 x framing anchors with 4/2.8 5.9 JD4
900mm centres max – mm nails per face min
to verandah plate
Deck battens to trusses 2.37 max 1x75mm long 3.6 JD5
@ 900mm centres batten screw
Top plates to slab M12 threaded rod @ 1200mm 20+ JD4
centres maximum & within min
100mm of lintels beside
openings
SHS to bearer to roof 21 2M16 gal bolts 20 min JD4
beams min
* Trusses, battens & tie down to top plate & speedy brace as truss manufacturer’s specifications.
Structural Drawings
GENERAL
1. At all stages of construction including wall construction, slab preparation, concrete pouring
and roofing, whole or partly constructed house elements must be fully supported against all
short or long term loads such as wind loading, self weight material, construction equipment,
building materials and construction personnel against failure or distortion of structural
elements. Adequate care must be taken to protect construction and other personnel against
injury.
W6107 de 3
Page 4
2. The structural elements have been drawn to approximate scales but sizing should not be
done by scaling off the structural drawings, the architectural drawing should be consulted for
this purpose – the structural design is my interpretation of the architectural drawings.
3. These drawings do not contain details of damp proofing, moisture barriers or termite
protection. These details should be incorporated into the structure to the relevant, current
Australian Standards, Local Authority requirements and Building Code of Australia.
4 All tradesmen should be appropriately qualified and their workmanship shall comply with
the relevant, current Australian Standards, Local Authority requirements and the Building
Code of Australia.
STEELWORK
1. Unless noted otherwise, steelwork including steel beams, steel brackets, rods, bolts, nuts,
washers, screws, nails etc shall be hot-dip galvanized or coated with an approved hot-applied
zinc-alume treatment.
2. All site welding and/or damage to the protective coating shall be cleaned back and re-coated
with an approved protection system. A protective system or remedial work shall be first
approved by the engineer before commencing.
3. In exposed areas or where specified on the drawings metal fixings shall be stainless steel
grade 304.
TIMBER SPECIFICATION
All timber and connections must comply with Residential Timber Framed Construction Code
AS1684.2 requirements and relevant proprietary timber manuals.
Note: Where fixings are not shown nominal fixings as per AS1684.2 table 9.4 (Nominal
Fixings for Timber Members) are recommended.
All exposed timbers must be CCA treated or paint protected. All bracing walls must be
anchored to upper roof/floor and to lower floor diaphragms with an appropriate anchoring
system as recommended per the AS1684.2 manual.
Custom made laminated beams must be installed as per manufacturer ’s specifications.
FOOTINGS Refer to footings and retaining wall design where
appropriate - separate notes attached.
WATERPROOFING. Waterproofing shall be as per Building Code of Australia.
TERMITE CONTROL. Termite control as per AS3660.1 – Protection of Buildings from
Subterranean Termites.
W6107 de 4
Page 5
MASONRY SPECIFICATION.
Construction: masonry work to comply with AS3700.
Masonry Unit Strength: f'uc = 15mPa (unconfined strength)
Mortar: cement 1, lime 1/2, sand 41/2 + methyl cellulose water
thickener
Grout: f'c = 20mPa (confined test) with 10mm aggregate with pouring
consistency & a minimum cement content of
300kg/cubic metre
Steelwork cover: as indicated on drawings but not less than 20mm from
the face of the grout to the reinforcement face.
Reinforcement laps: deformed bars - 40 times* bar diameter
Grout placement & compaction, careful placement to avoid segregation & disturbance of
mortar joints and compact with a 25mm rod. Note - all lintels must be fully propped during &
for a minimum of 14 days (or for longer if required) after the construction of upper walls,
slabs, roofs or other structural elements.
W6107 de 5
Used in these records
W6107 de f15.pdf - form 15 frame design.pdfRelated documentApplication case desk ↗
About this file
- File size
- 429 KB (small file)
- File type
No other editions are linked here.