Council archive · source document
W6107 de f15.pdf - form 15 frame design · OPW16/0220
Attached to the e-mail Operational works application OPW16/0220.
Report No: W6107 de.
Client Name: K Grandemange
Report Date: September 27, 2016
Site Address: No 61 Morinda Circuit, Noosaville.
Structural Details.
Tie down
Connection Max kN Fixing – beams are to fixed Uplift Joint
Uplift force both ends value kN group
Trusses to top plate & na As per truss manufacturer’s na na
beams specifications.
Main roof [email protected] 30x0.8 GI strap with 4/2.8 mm 4.7 JD4
900mm centres max nails per face or fix with joist min
hangers 6 nails per face
Deck [email protected] 2 x framing anchors with 4/2.8 5.9 JD4
900mm centres max – mm nails per face min
to verandah plate
Deck battens to trusses 2.37 max 1x75mm long 3.6 JD5
@ 900mm centres batten screw
Top plates to slab M12 threaded rod @ 1200mm 20+ JD4
centres maximum & within min
100mm of lintels beside
openings
SHS to bearer to roof 21 2M16 gal bolts 20 min JD4
beams min
* Trusses, battens & tie down to top plate & speedy brace as truss manufacturer’s specifications.
Structural Drawings
GENERAL
1. At all stages of construction including wall construction, slab preparation, concrete pouring
and roofing, whole or partly constructed house elements must be fully supported against all
short or long term loads such as wind loading, self weight material, construction equipment,
building materials and construction personnel against failure or distortion of structural
elements. Adequate care must be taken to protect construction and other personnel against
injury.
W6107 de 3
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
W6107 de f15.pdf - form 15 frame design.pdfRelated documentApplication case desk ↗
About this file
- File size
- 429 KB (small file)
- File type
No other editions are linked here.