Original source · versioned page text
Compiled Approved Plans MCU16 0138 & OPW16 0257 pdf
Plans and drawings
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn -
NOOSA COUNCIL
APPROVED PLAN
MCUU16/0138 & OPW16/0257
9 MAY 2017
DETERMINING THE RADIUS OF THE TPZ (TREE PROTECTION ZONE)
· DBH (DIAMETER AT BREAST HEIGHT) - NOMINAL TRUNK DIAMETER AT 1.4M ABOVE GROUND LEVEL
· TPZ SHOULD NOT BE LESS THAN 2M NOR GREATER THAN 15M (EXCEPT WHERE CROWN
PROTECTION IS REQUIRED).
· TPZ = DBH X 12
· TPZ OF PALMS, OTHER MONOCOTS, CYCADS & TREE FERNS SHOULD NOT BE LESS THAN 1M.
· VARIATIONS AND ENCROACHMENTS TO THE TPZ IN ACCORDANCE WITH AS 4970-2009.
NOTES:
POSITION CONSTRUCTION JOINTS AT 1m CENTRES &/OR ANY CHANGE OF CURVATURE OR AS
OTHERWISE SHOWN & OR SPECIFIED.
SET OUT EDGE WITH SMOOTH CONTINUOUS LINES IN BOTH HORIZONTAL & VERTICAL PLANES.
UNLESS OTHERWISE SHOWN AND/OR SPECIFIED ABUT EDGE FLUSH WITH FINISHED
SURFACES WITH A ROLLED/GRADUAL CHANGE OF ANGLES.
DO NOT ABUT AN ACCUTE ANGLE.
1200mm
1.4m
GROUND LINE
Crown DBH
600mm
TPZ
NOTES:
·
·
·
·
· 2x HOT DIPPED
· GALVANISED TRIPLE GRIP
SCREW TO FIX MITRED
· TIMBER EDGING
STREET TREE PLANTING DETAIL PLAN · TOGETHER, TYPICAL.
NOTES:
EXTENT OF PIT EXCAVATION TO BE 1800mm WIDE, MINIMUM (SUBJECT
TO FOOTPATH LOCATION). REMOVE ALL EXCAVATED FILL OFF-SITE. N.T.S.
CENTER TREE BETWEEN ROOT BARRIER & FOOTPATH, TYPICAL. CONCRETE EDGE
HARDWOOD
STAKES (2),
SEE SECTION
STREET TREE, VEGETATION PROTECTION FENCING, REFER
REFER DETAIL DETAIL 2, LD2
BELOW. STAR PICKET X 4, TYPICAL.
ROOTBALL EXTENT OF PIT EXCAVATION TO BE
1800mm x 1800mm IN AREA, MINIMUM,
REMOVE ALL EXCAVATED FILL
OFF-SITE.
'FIGURE 8' HESSIAN TREE TIE, TYPICAL
TOPSOIL WITH
MULCH ABOVE
ROOTBARRIER,
SEE NOTES FOOTPATH
BELOW
PLANT PIT 2X WIDTH OF 2x POT Ø SHRUB / GROUNDCOVER / TUFTY
RESEPCTIVE POT. SCARIFY ALL GRASS PLANT SPECIES PER PLAN
CONCRETE EDGING TO BE 100mm x PIT WALLS & BOTTOM, TYP. POT Ø
100mm PORTLAND GREY CONCRETE
OVER 95% COMPACTED SUBGRADE BACKFILL PLANT PIT WITH 100mm ORGANIC MULCH PER
PER DETAIL. EDGING TO EXTEND TO TOPSOIL AS PER GENERAL NOTES, GENERAL NOTES, KEEP MIN. 50mm
FOOTPATHS WHERE APPLICABLE WITH AVOID COMPACTION, TYP. FROM PLANT STEM. FORM SHALLOW
STREET TREE CENTRALLY LOCATED DISH DRAIN TO BASE OF PLANT, TYP.
GARDEN BED TOPSOIL AS
WITHIN GARDEN (ALLOWING FOR
PER GENERAL NOTES, AVOID
SERVICES SETBACKS), REFER TO
COMPACTION, TYP.
PLANS FOR PATH LOCATIONS.
NOTES: 100mm, TYP.
ENSURE CROWN OF ROOTBALL LEVEL IS 'AGRIFORM' SLOW RELEASE
SET HIGHER THAN ADJACENT FINISHED NOTES: FERTILISER. TYPE, SIZE & FORMULA
GROUND LEVELS TO PREVENT EXCESSIVE ENSURE CROWN OF ROOTBALL LEVEL IS PER GENERAL NOTES. DO NOT USE
2x ROOTBALL FOR BANKSIA, CALLISTEMON OR
PONDING AROUND ROOTBALL. WHEN SET HIGHER THAN ADJACENT FINISHED
DEPTH, TYP. GREVILLEA SPECIES, TYP.
FOOTPATH IS ADJACENT TO STREET TREE GROUND LEVELS TO PREVENT EXCESSIVE
INSTALL ROOT BARRIER TO FOOTPATH PONDING AROUND ROOTBALL. 150mm, TYP. 150mm DEEP CULTIVATED
SIDE OF PLANT PIT AS PER NOTES HEREIN. SUBGRADE, OR AS PER
EXISTING SUBGRADE, TYP. GENERAL NOTES, TYP.
50mm WIDE HESSIAN TREE TIES WRAPPED 50mm WIDE HESSIAN TREE TIES WRAPPED POTTED SHRUB, GROUNDCOVER OR TUFTY GRASS PLANTING
LOOSELY AROUND TRUNK, THEN A FIGURE 8 & LOOSELY AROUND TRUNK, THEN A FIGURE 8 &
SECURED TO STAKE WITH GALVANISED NAILS SECURED TO STAKE WITH GALVANISED NAILS N.T.S.
OR STAPLES. POSITION TREE TIE BETWEEN OR STAPLES. POSITION TREE TIE BETWEEN
1/3 TO 1/2 OVERALL HEIGHT OF TREE. 1/3 TO 1/2 OVERALL HEIGHT OF TREE.
2 - 50mm x 50mm x 2400mm F14 HARDWOOD
2 - 50 x 50 x 2400mm F14 HARDWOOD
CENTRALLY POINTED NON-TREATED STAKES CENTRALLY POINTED NON-TREATED STAKES.
(SHOWN PERPENDICULAR TO KERB FOR STAKES TO BE DRIVEN VERTICALLY INTO
GRAPHIC CLARITY ONLY). STAKES TO BE
GROUND OUTSIDE OF THE ROOTBALL &
DRIVEN VERTICALLY INTO GROUND OUTSIDE SHALL HAVE A FINISHED HEIGHT LOWER
LOT
ARBORGREEN 'ReRoute 600' OF THE ROOTBALL & SHALL HAVE A FINISHED
THAN THE TREES LOWER LATERAL LIMBS.
LINEAR ROOT BARRIER - 4m HEIGHT LOWER THAN THE TREE'S LOWER Road verge /
LONG PANELS CENTRED AT LATERAL LIMBS. FORM SHALLOW SAUCER SHAPED lot boundary
TRUNK WITH ROOT FORM SHALLOW SAUCER SHAPED DEPRESSION AROUND BASE OF PLANT. typical, confirm
DEFLECTING RIBS DEPRESSION AROUND BASE OF PLANT. KEEP MULCH NOM. 50mm FROM TRUNK with Super
(OR EQUAL) FACING TREE KEEP MULCH 50mm FROM TRUNK BASE. BASE.
& INSTALLED PER
MANUFACTURER'S 100mm DEEP ORGANIC MULCH AS 100mm DEEP ORGANIC MULCH AS
INSTRUCTIONS. SPECIFIED. MOUND MULCH AT EDGE OF SPECIFIED. MOUND MULCH AT EDGE OF
PLANT PIT TO COLLECT WATER TO FALL PLANT PIT TO COLLECT WATER TO FALL 600mm
DOWN EDGES OF PLANT PIT. DOWN EDGES OF PLANT PIT. DO NOT MULCH typical
WITHIN 50mm OF PLANT STEM.
EXISTING CONCRETE FOOTPATH
Varies,
refer
Plans
TREE PIT TO BE EXCAVATED TO NOMINAL
DEPTH OF 600mm. BACKFILL HOLE WITH TREE PIT TO BE EXCAVATED TO NOMINAL
TOPSOIL PER SPECIFICATIONS FIRMING DEPTH OF 600mm. BACKFILL HOLE WITH
PROGRESSIVELY. EXCESS EXCAVATED SOIL 100% FRIABLE AMELIORATED SITE TOPSOIL
TO BE REMOVED OFF SITE. FIRMING PROGRESSIVELY. ALL EXCAVATED
FILL TO BE REMOVED OFF SITE. Per Engineer
PROVIDE CLEAN CONNECTION TO ROAD
DRAINAGE AS ADVISED ON SITE BY CIVIL SCARIFY PIT WALLS & CULTIVATE PIT
ENGINEER. TYPICAL: 100mm DEEP UNIFORM BOTTOM 150mm, TYP. Per Engineer
GRAVEL LAYER. SLOW RELEASE FERTILIZER AS PER
150mm CULTIVATED SUBGRADE & PIT WALLS. MANUFACTURERS SPECIFICATIONS &
ROAD Back of kerb Turf Roll, typical
GENERAL NOTES.
SLOW RELEASE FERTILIZER AS PER Kerb invert
MANUFACTURERS SPECIFICATIONS & Kerb lip
GENERAL NOTES.
N.T.S. N.T.S. TURFING TO ROAD VERGE & LOT AREAS N.T.S.
Typical Plan Detail
S1709935
1703-A anembo consultants
THE PROPERTY CLINIC TWO DUPLEXES Landscape Architects
Environmental
Project Management
This document is the copyright of anembo consultants & shall
LOT 6 RP79817, LOT 18 RP66590, anembo consultants pty.ltd. A.B.N. 75 089 473 156
Sunshine Coast: PO Box 24 Moffat Beach QLD 4551
not be copied without written approval, nor shall it be used 111 & 113 GYMPIE TERRACE, Ph: 07 5437 0000 Fax: 07 5437 0088
except for the development and the site specified. Scale
can not be guaranteed when printing from PDF files. NOOSAVILLE, QLD 4566 e-mail: [email protected] www.anembo.com
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.