Council archive · source document
Engineering Drawings · 142007.743.03
S12 drop vertical bar
S12 corner bars @ 150 crs
N16 corner bars @ 200 crs (Below Ground)
350mm min lap
N16 corner bars @ 100 crs (Above Ground)
Radius 155mm
S12 Horizontal steel to be 350mm min lap
hooked with; Radius 155mm
40
50mm pin diameter min
LINDSAY CONSULTING PTY
LINDSAY CONSULTING PTY LTD
250mm lap LTD
30mm min cover so bars shall be
T
slightly rotated for min cover RPEQ 4928
65
T
OFF. 2C/82 PARKER STREET, MAROOCHYDORE PH 54 792 118
THIS DRAWING REMAINS THE PROPERTY OF
65
LINDSAY CONSULTING PTY LTD AND IS FOR
40 THE SOLE USE OF THE CLIENT. NO PART
MAY BE USED IN PART OR WHOLE WITHOUT
65 PRIOR EXPRESS WRITTEN CONSENT OF
WALL REINFORCEMENT AS PER
LINDSAY CONSULTING PTY LTD
DETAILS
65
WALL REINFORCEMENT AS PER CLIENT AND PROJECT DESCRIPTION
DETAILS
ONTREND GROUP
PROPOSED POOL
UNIT 2 NO.36 VENTURA ST
SUNRISE BEACH
DRAWING TITLE
TYPICAL REINFORCEMENT
DETAILS
SCALES
CORNER RADIUS LESS THAN 300mm
ALTERNATE CORNER RADIUS LESS THAN 300mm
Extra S12 1500 long
spaced 300 vertically
75 cover to inside face
S12 Verticals @ 200 crs
S12 Horiz @ 200 crs
R pro
SURVEY DATUM
(a
Line of
30 x.
p
0 )
excavation
.
T
ASSOCIATED CONSULTANTS
Position outside horizontal
reinforcing with 60 MIN cover
to excavated face
PLAN
WALL CORNER DETAIL
FOR RECTANGULAR POOLS
CORNER RADIUS 300mm OR GREATER
R pro
(a
30 x.
p
REVISION LIST
0 )
A ORIGINAL ISSUE 26/07/23
PLAN
BOND BEAM CORNER DETAIL Computer File
230693PL.DWG
FOR RECTANGULAR POOLS DRAWING NUMBER
23-0693-PL4
SHEET
4 A
REV.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Engineering Drawings.pdfRelated documentApplication case desk ↗
About this file
- File size
- 377 KB (small file)
- File type
No other editions are linked here.