Council archive · source document
Request for Further Information - 010.2007.00000567.001 [As Published] · 132007.567
Tracy Arthur, 5449 5228
Email: [email protected]
Application Ref: 2007/567
30 April 2007
John Wentzel
1/23 Edward Street
NOOSAVILLE QLD 4566
Dear Sir,
Re: Application for Material Change of Use for Multiple Housing - Type 2 Duplex
situated at 23 Edward Street, Noosaville described as Lot 0,1 & 2 GTP 492
I refer to the above application for Material Change of Use for Multiple Housing - Type 2 Duplex
and wish to advise that following preliminary examination of the application, the following
information is required to be submitted:-
Land Use
1. Provide amended plans which demonstrate compliance with the following:-
2
1.1. Gross Floor Area - The proposed development has a gross floor area of 348m ,
2
which exceeds the maximum allowable requirement of 275m (0:45).
2
1.2. Site Cover – The proposed development has a gross floor area of 291m , which
2
exceeds the maximum allowable requirement of 245m (40%).
1.3. Setbacks – Awnings/roof encroach within side and rear setbacks requirements of
1.5 metres and 6 metres.
Amended plans should clearly illustrate the location of the building in respect to property
boundaries (ie. both ground and first floor plans do not identify property boundaries).
2. The current design does not have provision for landscape screening to occur in front of
the fence. Accordingly, the front fence should be setback a minimum of 1 metre from the
front property boundary, provided that at least half of the length of the fence is setback a
minimum of 2 metres, with articulation provided at maximum of 3 metre intervals.
3. Garages are required to be designed and sited not to dominate the street front. This can
be achieved by ensuring the garages are stepped back a minimum of 600mm from each
other, in relation to the frontage.
Land Development
4. Provide a preliminary stormwater disposal plan that demonstrates that the proposed
development does not result in an increase in stormwater runoff from the site. The plan is
to include:
4.1. Provision for an on-site rainwater storage system. Roof runoff shall be directed to
the rainwater storage system or tank (minimum storage 5000 litres per dwelling
unit) that is plumbed to service the toilets and landscaping areas.
Award Winner - Australian Clean Beach
Challenge 2004 Litter Prevention
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 1 page
Page 2
4.2. Provision for the disposal of natural surface stormwater runoff from the adjoining
properties to prevent additional ponding of stormwater on the adjoining properties.
Site levels of the adjoining properties will be necessary to determine if the filling of
the site will create any additional ponding.
5. Amended plans, which illustrate a manouvring space instead of one of the visitor car
parks. The space should be designed to enable vehicles to enter and exit the garages in
accordance with AS/NZS 2890.1:2004.
6. Provide a certified copy of the as constructed survey of the existing sewer centre line (not
manhole lid centres) and depths of the sewer to demonstrate that the proposed pools do
not encroach into the zone of influence ie. 45 degrees angle from the invert of the sewer
based on finished surface levels.
Please provide four (4) copies of all information that you are providing. In addition, it would
assist Council if you could also provide an electronic copy of your response.
Please be aware that under Section 3.2.12 of the Integrated Planning Act, the applicant is to
respond to any information request within 12 months of the request or otherwise, the application
lapses.
Under the provisions of the Integrated Planning Act 1997, you as the applicant, have three
options available in response to this Information Request. You may give the assessment
manager (in this instance Council) and each referral agency (if any):-
1. all of the information requested; or
2. part of the information requested together with a letter asking the assessment manager
and each referral agency to proceed with the assessment of the application; or
3. a letter:-
3.1. stating that you do not intend to supply any of the information requested; and
3.2. asking the assessment manager and each referral agency to proceed with the
assessment of the application.
The above information is required to be submitted, prior to assessment of the application. If any
further matters arise as part of assessment of this application, you will be advised accordingly.
Should you have any further queries in relation to the above, please do not hesitate to contact
Tracy Arthur on the above number.
Yours faithfully,
Tracy Arthur
PLANNING OFFICER
Award Winner - Australian Clean Beach
Challenge 2004 Litter Prevention
Used in these records