Change proposal plans · 51983.3225.22
Plans and drawings: the text below has words only, no drawings.
Very large file (10.2 MB): may take a few minutes to open.
NOTE
UNLESS NOTED OTHERWISE, ALL EXISTING
BUILT WORKS ARE TO REMAIN. FOR FURTHER
CLARIFICATION ON EXTENT OF DEMOLITION
NOTES
1. ALL CONSTRUCTION WORK UNDERTAKEN
|S TO COMPLY WITH THE NATIONAL
CONSTRUCTION CODE (BCA), RELEVANT
NOTE:
THESE DRAWINGS ARE DESIGN CONCEPTS
ONLY AND SHALL NOT BE USED IN ANY
WAY FOR STRUCTURAL PURPOSES. REFER
TO STRUCTURAL ENGINEER'S DETAILS
WORKS, REFER TO PROPOSED FLOOR PLAN FOR AUSTRALIAN STANDARDS AND
PROPOSED RECONFIGURATION LAYOUT, WALL APPLICABLE LOCAL AUTHORITY FOR ALL MEMBER SIZES, SPECIFICATIONS
SETOUT DIMENSIONS AND OPENING LOCATIONS. REQUIREMENTS. AND SITE SPECIFIC STRUCTURAL
2, ALL SETBACK/SETOUT DIMENSIONS ARE
TO BE CHECKED AND VERIFIED ON SITE
REQUIREMENTS.
PRIOR TO CONSTRUCTION.
NOTE:
ROOM DIMENSIONS
N\ SHOWN ARE TO
ADJOINING ADJOINING FINISHED WALL FACES.
VILLA VILLA oq -
ROADWAY
. BOUNDARY ADJOINING LEGEND
_ _ @ - _
VILLA Se
COL STEEL COLUMN
PP N J DP DOWNPIPE
| | - TP TIMBER POST
-w we WASTE PIPE
_ _ _ _ _____EAVES LINE OV@&¥————— >a
| rT <a3 BATHROOM HEATER LIGHT AS SPECIFIED
388
> f SAG oO EXHAUST FAN AS SPECIFIED
= | aa
| 8 | | INO s ° LED DOWNLIGHT AS SPECIFIED
3 ° i oN
| |= = | 8 SMOKE DETECTOR TO LOCAL
5 6 ~ AUTHORITY REQUIREMENTS
ig a | ia
f | \
| | ¥ LOFT ¥ = ) CEILING FAN AS SPECIFIED
5 6485x5315mm (APPROX) 5 < ~
| iS PLASTERBOARD | Z
| 2 =z | a
= , =
sb q | ° ° | NOTE.
| | LIGHTING LAYOUT SHOWN IS NOMINAL.
on) | | BUILDER TO CONFIRM SUITABLE LAYOUT
| | AGAINST ENERGY EFFICIENCY REPORT
7 AND LOCAL AUTHORITY REQUIREMENTS
ADJOINING AND COORDINATE WITH ELECTRICIAN
SS CCEAVESLINEOVER st” ff SHARED
\s— = ——
ADJOINING BOUNDARY ROADWAY
SHARED S BOUNDARY ©
(DEDICATED LOT
ROADWAY EXCLUSIVE USE AREA)
(01. \ REFLECTED CEILING PLAN - LEVEL 3
Yo) SCALE 1:100
AN
CRITICAL NOTE: PARTITION WALLS SHOWN ARE BASED ON 70mm WIDE STUD FOR
APPROVAL PURPOSES ONLY. REFER TO STRUCTURAL ENGINEER'S DETAILS FOR ALL
FRAMING SIZING AND STRUCTURAL REQUIREMENTS THROUGHOUT PROPOSED
WORKS. WHERE 90mm STUD FRAMES ARE REQUIRED TO SUIT PROPOSED
STRUCTURE, BUILDER TO MAINTAIN EXTERNAL BUILDING FOOTPRINT AND ADJUST
ROOM SIZES ACCORDINGLY ON INTERNAL SIDE, ENSURING MINIMUM INTERNAL
CIRCULATION WIDTHS ARE MAINTAINED (WHERE REQUIRED). ALL DIMENSIONS
SHOWN ARE FOR APPROVAL PURPOSES ONLY, STRUCTURAL LAYOUT TO BE
CONFIRMED ON SITE BY PROJECT ENGINEER & BUILDER PRIOR TO CONSTRUCTION.
NOTES:
4, THIS IS A COMPUTER GENERATED DRAWING. DO NOT AMEND BY HAND.
AMENDMENTS
REV
DATE __DESCRIPTION
e FOR APPROVAL
PROJECT
DRAWING CREATED SCALE @A3
2. THIS DRAWING SHOWS DESIGN INTENT ONLY. ALL DIMENSIONS AND AUG 2023 11
SETOUTS ARE TO BE CHECKED ON SITE PRIOR TO ConSTRUCTION | A ]17.08,2023] ISSUE FOR BUILDING APPROVAL G PROPOSED RESIDENTIAL ALTERATIONS 00
3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS B | 14.01.2025) PROJECT SCOPE ADJUSTMENTS Ge ‘ADDRESS PROJECTNO. REVISION www.gtgroup.net.au
ARE TO BE REPORTED TO THE DESIGNER PRIOR TO CONSTRUCTION. 22048 B drake A “
4, DONOT SCALE THIS DRAWING. 2/30 HASTINGS STREET, NOOSA HEADS QLD 4567 aes. [email protected]
cr GROUP BULOING DESIGN, THESE DRAWINGS ARE PROTECTED BY [numion cB avin ows. no Ra CSILe
THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED | ORIGINAL SHEET SIZE: A3 (420x297mm REFLECTED CEILING PLAN - LEVEL 3 A112 ODETTE)
WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Change proposal plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 10.2 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.