Change proposal plans · 51983.3225.22

of 25

Check the original when the exact wording matters.

Plans and drawings: the text below has words only, no drawings.

Very large file (10.2 MB): may take a few minutes to open.

Log in to see the plans as drawn
ADJOINING
VILLA

BOUNDARY

 

4
q

ADJOINING
VILLA
ROADWAY

BOUNDARY,

ADJOINING
VILLA

@—_

 
  

 

 

 

A

Tian

SA
SS

OT at

NDAD
re
BS

Ss

OOO

 

 

NX
\
~

XN

x

\
NXQQOQOOQYAY

 

Z
Z
4
Ze

NN
NONN
XQ s_e
NX dye
\
SMYYYCYY

SAAS /

w*X
\

Y

TNO
YLLLTT ALS,
SLL) LLL.
SILLA L LL.

GILLES

“OIL Lp
%
LLG |

r=
ASN \
\ IN’
ane
\
Let
77

\
\

4

S\

K
NOTE NOEL
STS
ONY

YY

Sy

NS
\YX

MQ nv
“NOTE1

LULL

\
NO
SA

 

BOUNDARY

  

 

(DEDICATED LOT
EXCLUSIVE USE AREA)

7

LEGEND

COL STEEL COLUMN

BOUNDARY

NOTE

UNLESS NOTED OTHERWISE, ALL EXISTING
BUILT WORKS ARE TO REMAIN. FOR FURTHER
CLARIFICATION ON EXTENT OF DEMOLITION
WORKS, REFER TO PROPOSED FLOOR PLAN FOR
PROPOSED RECONFIGURATION LAYOUT, WALL
SETOUT DIMENSIONS AND OPENING LOCATIONS.

AS

NOTES

1. ALL CONSTRUCTION WORK UNDERTAKEN
|S TO COMPLY WITH THE NATIONAL
CONSTRUCTION CODE (BCA), RELEVANT
AUSTRALIAN STANDARDS AND
APPLICABLE LOCAL AUTHORITY
REQUIREMENTS.

2, ALL SETBACK/SETOUT DIMENSIONS ARE
TO BE CHECKED AND VERIFIED ON SITE
PRIOR TO CONSTRUCTION.

NOTE:

THESE DRAWINGS ARE DESIGN CONCEPTS
ONLY AND SHALL NOT BE USED IN ANY
WAY FOR STRUCTURAL PURPOSES. REFER
TO STRUCTURAL ENGINEER'S DETAILS
FOR ALL MEMBER SIZES, SPECIFICATIONS
AND SITE SPECIFIC STRUCTURAL
REQUIREMENTS.

 

 

NOTE:

ROOM DIMENSIONS
SHOWN ARE TO
FINISHED WALL FACES.

Parwn>

16.
17.

[DEMOLITION NOTES. |

DEMOLISH EXISTING WALLS TO EXTENT SHOWN.
DEMOLISH EXISTING DOORS AND WINDOWS.
DEMOLISH EXISTING STAIRS AND HANDRAIL.
DEMOLISH EXISTING CONCRETE GROUND SLAB.
DEMOLISH EXISTING SCREEN STRUCTURES.
DEMOLISH EXISTING BRACING FRAMES. NOTE:
CONFIRM SUFFICIENT RECTIFICATION WITH
STRUCTURAL ENGINEER TO SUIT NEW WORKS.
DEMOLISH EXISTING GROUND PAVERS TO
EXTENT SHOWN.

DEMOLISH EXISTING JOINERY BENCH.

REMOVE EXISTING TUB, EQUIPMENT AND
CUPBOARDS AND RETAIN FOR REINSTATEMENT
(CLIENT TO CONFIRM).

. DEMOLISH EXISTING HOT WATER SYSTEM AND

ASSOCIATED WORKS.

. DEMOLISH EXISTING FLOOR TO EXTENT SHOWN.
. DEMOLISH EXISTING SANITARY FIXTURES

INCLUDING TOILETS, SHOWERS AND BASINS.

. DEMOLISH EXISTING KITCHEN JOINERY. RETAIN

EXISTING EQUIPMENT FOR REINSTATEMENT
(CLIENT TO CONFIRM).

. DEMOLISH EXISTING COLUMN. NOTE: CONFIRM

SUFFICIENT RECTIFICATION WITH STRUCTURAL
ENGINEER TO SUIT NEW WORKS.

. DEMOLISH EXISTING AIR CONDITIONER AND WALL

MOUNTING BRACKETS.
DEMOLISH EXISTING TELEVISION.
DEMOLISH EXISTING DOWNPIPE.

 

 

18. DEMOLISH EXISTING DECKING TO EXTENT
SHOWN.
DEMOLISH EXISTING DECK BALUSTRADE.

DEMOLISH EXISTING BEDROOM JOINERY.

\
SN
SS

N
SS
\XN
YA
\S
A
\S
So
ae
2s.
&
\
\
\
\
\

 

NIXON
NXQOQOOYAY

19.
20.

OXON

ADJOINING
SHARED
ROADWAY

5

St YL

 

 

r

 

 

 

 

 

BOUNDARY

 

 

 

 

 

 

BOUNDARY
(DEDICATED LOT
EXCLUSIVE USE AREA)

7

ADJOINING
SHARED
ROADWAY

(01. \ DEMOLITION CEILING PLAN - LEVEL 1

 

 

NOTE:

21
22
23
24
25

26.

DEMOLISH EXISTING FLOOR TILES TO EXTENT
SHOWN.

DEMOLISH EXISTING CARPET FLOORING TO
EXTENT SHOWN.

DEMOLISH EXISTING ROOF SHEETING.
DEMOLISH EXISTING EAVES GUTTERS.
DEMOLISH EXISTING CEILING FITTINGS AND
FIXTURES.

DEMOLISH EXISTING CEILING LINING.

PLANS REPRESENT GENERAL DESIGN
DEMOLITION INTENT ONLY. FULL EXTENT OF
DEMOLITION REQUIRED TO SUIT PROPOSED

 

Yo) SCALE 1:100

WORKS TO BE CONFIRMED ON SITE.

 

NOTES:
4, THIS IS A COMPUTER GENERATED DRAWING. DO NOT AMEND BY HAND.

AMENDMENTS
REV___DATE

PROJECT DRAWING CREATED SCALE @A3

DESCRIPTION

 

 

ile cres cetacean FOR APPROVAL reuneoens
SETOUTS ARE TO BE CHECKED ON SITE PRIOR TO CONSTRUCTION. ‘A _]17.08,2023] ISSUE FOR BUILDING APPROVAL CB PROPOSED RESIDENTIAL ALTERATIONS 00

3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHINTHE DRAWINGS | 8 | 14.01.2025] PROJECT SCOPE ADJUSTMENTS SB ADDRESS PROJECT NO. REVISION www.gtgroup.net.au
ARE TO BE REPORTED TO THE DESIGNER PRIOR TO CONSTRUCTION, © | 15.01.2025) UPDATED PROJECT SCOPE ADJUSTMENTS GB 22048 c RUG Es [lt NES

4. DONOT SCALE THIS DRAWING 2/30 HASTINGS STREET, NOOSA HEADS QLD 4567 a [email protected]

{GT GROUP BULOING DESIGN. THESE ORANINGS ARE PROTECTED BY [numion cB avin OHNO CIES

THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED | ORIGINAL SHEET SIZE: A3 420x297mm) DEMOLITION CEILING PLAN - LEVEL 1 A055 ODETTE)

WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.

Used in these records

About this file

File size
10.2 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Change proposal plans.pdf · 10.2 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.