Qualtest Geotechnics Slope Stability Assessment Tool – Hargreaves & Kidd (2012)
Grade (14) Type of Fill Level Factor Grade (20) In-ground Tank Level Factor
✓ AS3798 (Level 1 Certified) L 0.7 >10m from footing L 0.7
Compacted but not certified M 1.0 ✓ 6 to 10m from footing M 1.0
Track-rolled fill (Clay) H 1.2 3 to 6m from footing H 1.2
Tracked-rolled fill (sand) VH 1.5 <3m from footing VH 3.0
Obvious compressible fill VH 3.0 Not known VH 4.0
(15) Wastewater, Sewerage Level Factor Grade (21) Landscaping Level Factor
Fully sewered M 0.8 AS2870-2011 compliant L 0.7
Onsite surface disposal within H 1.5 (+upslope
10m of structure diversion bund/swale)
✓ Onsite surface disposal > 10m M 0.9 ✓ AS2870-2011 compliant M 0.9
of structure Non-AS2870-2011 H 1.5
Onsite subsurface disposal VH 2.0 compliant
within 10m of structure Obvious evidence of water VH 2.5
Onsite subsurface disposal > H 1.0 ponding/poor drainage
10m of structure Not known VH 4.0
Not known VH 4.0
Grade (22) For Upslope Level Factor
Grade (16) Stormwater Disposal Level Factor Boulder / Flow Event
To the kerb or council system M 0.7 Only
✓ Rainwater tank with engineer M 0.7 Engineer designed L 0.7
approved overflow catching net
Rainwater tank without engineer H 1.2 Engineer designed M 0.9
approved overflow upslope bund
Dispersed >10m downslope M 1.0 Engineer designed M 1.0
(approved) upslope fence
Directly onto ground M 1.5 Non engineer approved H 1.5
Onsite rubble pit VH 3.0 method
Not known VH 4.0 No action taken VH 4.0
Grade (17) Expandable / Mechanical Level Factor Summary
Stormwater & Drainage Pipe 1 Natural Soil Conditions 0.8
Connectors
2 Slope Shape/Appearance 0.9
Specifically, engineer designed L 0.8
and inspected 3 Site Geology 1.0
✓ As per AS2870-2011 for M 1.0 4 Soil Profile 1.5
extremely reactive sites
5 Regional Position on Hillside 1.2
Not used VH 2.0
Not known VH 4.0 6 Evidence of Groundwater 0.7
7 Evidence of Slope Instability 1.2
8 Cut depth 1.5
Grade (18) Footing System Level Factor 9 Cut batter angle 0.5
Timber/flexible floor L 0.7
10 Cut batter support 1.5
(suspended, able to be re-
leveled) 11 Fill depth 1.5
✓ Engineer designed suspended M 1.0 12 Fill batter angle 0.5
slab 13 Fill batter support 1.8
As per AS2870-2011 H 1.2
14 Type of fill 0.7
Less than AS2870-2011 VH 2.0
generally 15 Wastewater system (sewerage etc) 0.9
applies to old houses) 16 Stormwater disposal 0.7
Not known VH 4.0 17 Expandable/mechanical pipes 1.0
18 Footing system 1.0
19 The foundation strata 0.7
Grade (19) The Foundation Strata Level Factor
20 In-ground tanks 1.0
✓ Bedrock L 0.7
21 Landscaping 0.9
Residual Soil M 1.0
22 Upslope boulder/flow events only N/A
Transported Soil H 1.2
Fill VH 3.0
Remediation Output = 0.46
Not Known VH 4.0
Document Set ID: 22750694
Version: 1, Version Date: 03/01/2024
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.