Original source · versioned page text
221633 Civil_Combined
Original PDF page 5, section 1. The text section number identifies this passage in the reader.
4
121.
118.4
122.0
S
120.4
SW
120.6
2
120.2
3
120.8
C331 C331
.2
121
EXISTING 1 IN 4 MAX
S
BATTER TO REMAIN
SW
.2
119
.2
118
II
122.2
.8
1.6
118
12
S
121.0
SW
119.8
II
121
.4
119.0
120.0
119.8
120.0
120.2
120.4
120.6
120.8
S
121.8
II
6
119.
1 IN 4 MAX BATTER
S
SW
118.2
118.2 118.6
1
6
4
2
0
8
1.2
.4
8.6
119.
119.
119.
119.
118.
118
12
C331 EXISTING PAVEMENT UNDER CARPARK
11
.4
119
MAY BE RETAINED OR RE-PURPOSED IF
S
SUITABLE. CONTRACTOR TO INVESTIGATE
SW
122.4
DURING DEMOLITION AND NOTIFY
ENGINEER TO CONFIRM SUITABILITY
RET
WALL
S
121.8
SW
RET
118.4
WALL S
120
120
.0
SW
.4
122
120
.2
120.8
RET
.6
119.2 121.2 WALL
.8
118
118
.8
121.6
S
119.0 119.8 121.0 121.4
120.0
118.8
SW
.2
122
SW
S
SW
2.2
FILENAME: \\AD.EDGECE.COM\JOBS\220000\221633-NOOSA CHRISTIAN COLLEGE LRC ADMIN REFURB\EDWG\CIVIL\221633 C301 BULK EARTHWORKS PLAN.DWG
12
119.6
SW
S
SW
.4
119
NOTE
A SOILS INVESTIGATION HAS BEEN CARRIED OUT BY SOILS SURVEYS
ENGINEERING, REFERENCE No. 309-2873, DATED MAY 2009. THIS
REPORT MUST BE READ IN ITS ENTIRETY PRIOR TO CONSTRUCTION
BEING UNDERTAKEN.
LEGEND
ANY UNSUITABLE MATERIAL ENCOUNTERED IS TO BE TREATED IN
PROPERTY BOUNDARY
ACCORDANCE WITH THE GEOTECHNICAL REPORT.
EXISTING MINOR &
11.1 MAJOR CONTOUR (0.100m) DEPTH RANGE LEGEND
TEMPORARY BATTERS ARE TO BE CONSTRUCTED IN ACCORDANCE
EXISTING BUILDING CUT FILL WITH THE GEOTECHNICAL REPORT
RET WALL EXISTING RETAINING WALL
0.00m - 0.25m
EXISTING SWALE
SW EXISTING STORMWATER EARTHWORKS VOLUMES
W EXISTING WATER
0.25m - 0.50m
200mm STRIP = 165m3
WARNING
0.50m - 1.00m CUT = 185m3 THE CONTRACTOR SHALL CONFIRM THE LOCATION OF ALL EXISTING
S EXISTING SEWER
FILL = 15m3 SERVICES ON AND EXTERIOR TO THE SITE INCLUDING WATER MAINS,
E EXISTING ELECTRICAL NOTE: THE ABOVE QUANTITIES DO NOT ALLOW SEWER MAINS, GAS MAINS, TELECOMMUNICATIONS CABLES, ELECTRICAL
1.00m - 1.50m
EXISTING ELECTRICAL OVERHEAD FOR DETAILED BACKFILL BEHIND RETAINING CABLES, AND STORMWATER PIPES. ANY DAMAGE TO EXISTING SERVICES
N
WALLS. CONTRACTOR TO MAKE ALLOWANCE. SHALL BE REPAIRED AT THE CONTRACTORS EXPENSE.
T EXISTING TELECOMMUNICATIONS 1.50m - 2.00m
PLOT DATE: 30.01.2023
PROPOSED MINOR &
11.1 MAJOR CONTOUR (0.100m) 2.00m - 3.00m
PROPOSED BUILDING
Project Name Drawing Title
> 3.00m Brisbane . Australia
PROPOSED BATTER TOP RPEQ NAME: ERIN HOGAN 1st Floor, 28 Balaclava Street.
Woolloongabba,
NOOSA CHRISTIAN COLLEGE BULK EARTHWORKS PLAN
Queensland, 4102,
PROPOSED BATTER TOE NORTH RPEQ No: 21411 Australia
20 COOROY BELLI CREEK ROAD
BH BOREHOLE COOROY QLD 4563
T: +61 7 3392 3671
0 2 4 6m DATE: 30.01.23 www.edgece.com E: [email protected] Client Project No.
PAYNTERS 221633 FOR APPROVAL
The concepts + information contained in this document are the copyright of EDGE Consulting Engineers.
SIGN: Use or copying of this document in whole or in part without the written permission of EDGE Consulting Engineers
Designed Drawn Checked Scale @ A1 Drawing No. Revision
SCALE 1:100 @A1 P1 30.01.23 FOR APPROVAL ST KO constitutes an infringement of copyright.
0 mm 10 20 30 40 50
Rev Date Description By Chk DO NOT SCALE DRAWINGS. IF IN DOUBT, ASK! ST ST KO 1:100 C301 P1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file