Operational Woks Application OPW18-0071, Plans 2 of 2 · OPW18/0071
Plans and drawings: the text below has words only, no drawings.
NOTES: 80 PERCENT ENERGY EFFICIENT GLOBES TO ALL FIXED INTERNAL LIGHTING. MINIMUM 4 STAR ‘MEPS’ RATED AIR CONDITIONERS WHERE FITTED. SYMBOLS ARE INDICATIVE ONLY. EXACT MODEL TO BUILDER'S SPECS. MECHANICAL VENTILATION TO ENS. & BATH TO BE IN ACCORD. WITH THE BCA PART 3.8.5 & AS 1668.2 LEGEND: DW DISHWASHER PH PHONE TV TELEVISION FR FRIDGE RH RANGEHOOD EX EXTERNAL AIC AIR CONDITIONER HW HOTWATER MH = MANHOLE (CY ELECTRICAL PLAN 1: 100 Ne ELECTRICAL LEGEND: SYMBOL | DESCRIPTION SWITCHBOARD/METER BOX fam | DISTRIBUTION BOARD ~ SINGLE POWER POINT - 300 above FFL mm =| DOUBLE POWER POINT - 300 above FFL a SINGLE POWER POINT - 1200 above FFL (UNO XQ __| DOUBLE POWER POINT - 1200 above FFL UNO| mEX | WEATHERPROOF POWER POINT [--———| | FLUORESCENT CEILING BATTEN © LED LIGHT FITTING (ROUND} ol LED LIGHT FITTING (SQUARE) @® FEATURE PENDANT +O | WALL MOUNTED LIGHT FITTING ° RECESSED DOWN LIGHT LIGHT FITTING - FEATURE RAIL Oo _| UGHT SWITCH - 1000 above FFL (UNO) wi _| LIGHT SWITCH WITH DIMMER CONTROL | 2-WAY LIGHT SWITCH ISOLATION SW. FOR HARD WIRED FIXTURE phPH | TELEPHONE POINT rhIV | TELEVISION POINT VTS | CEILING FAN - @1200mm - MINIMUM N wa Ts, _ | CEILING FAN - @1200mm - MINIMUM Sfp | WITH FLUORESCENT LIGHT ) [SMOKE ALARM - HARD WIRED AIR CONDITIONER UNIT @ HOT WATER UNIT (storage) HOT WATER UNIT (gas) WIRING FAN, LIGHT COMBINATION FAN, HEAT, LIGHT COMBINATION LIGHT SENSOR ITEM DOWNLIGHIS - INTERNAL - LED DOWNLIGHTS - EXTERNAL - LED FLOURO BATTENS - INTERNAL FLOURO BATTENS - EXTERNAL FLOURECENT LIGHT FITTING - ROUND FEATURE PENDANTS FAN LIGHTS FAN HEAT LIGHTS WALL LIGHTS - INTERNAL WALL LIGHTS - EXTERNAL SENSORS POWER POINTS - SINGLE POWER POINTS - DOUBLE POWER POINTS - EXTERNAL SMOKE ALARMS TELEPHONE POINTS TELEVISION POINTS CEILING FANS CEILING FANS WITH LIGHT DOWN LIGHT - H20 PROOF bespeke building design Russell Willcox Principal Designer/Otrector WO so esse, ae a. 2 s THESE DRAWINGS AND DESIGN ARE issue | DATE [DRWNICHKD COMMENTS PROJECT DATE COPYRIGHT AND WILL NOT BE USED - DESIGN RECEIVED & ACCEPTED OR REPRODUCED BY ANY MEANS, 19/12/2017, RW. | RW | PREUMINARY PLANS PROPOSED RESIDENCE ELECTRICAL PLAN WHOLLY OR PARTLY WITHOUT PRIOR A |15701/2018] RW | RW. GENERAL AMENDMENTS CLIENT SALES PROJECT STATUS BESPOKE BUILDING DESIGN 8 31/01/2018) AB | RW /CONSTRUCTION DRAWINGS CONSTRUCTION DRAWINGS DO NOT SCALE FROM THIS DRAWING | ©. oveaaotg|_ew_| av REIANING watt ADDED CLIENT LOCATION SCALE SHEET SIZE Rca CLASS | ISSUE VERIFY ALL DIMENSIONS PRIOR TO MACINTOSH, Douglas LOT 37 ON $P254354 INDICATED) AS Q c | COMMENCEMENT OF ANY SITE WORKS DRAWING FILENUMBER | PAGE ) AND REFER ANY DISCREPANCIES TO BREWERS ROAD BI71211 Supp-1 BESPOKE BUILDING DESIGN COORAN, QLD
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Operational Woks Application OPW18-0071, Plans 2 of 2.pdfRelated documentApplication case desk ↗
About this file
- File size
- 3.2 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.