Council archive · source document
MCU14/0045 & OPW14/0268: Appendix D - Noosaville Locality Code
Appendix D: Noosaville Locality Code
PERFORMANCE CRITERIA ACCEPTABLE SOLUTIONS COMMENTS
b) the design consists of a suspended floor
construction; AND
S17.4 Car parking and maneuvering areas are
constructed at a level that permits the parking
area to drain from the site by gravity means,
without the need for mechanical pumping;
AND
S17.5 Basements for residential uses have
flood immunity above the Q100 where
alternative means to mechanical pumping are
used to achieve such immunity; or
S17.6 Basements for non-residential uses
have flood immunity above the Q100 that may
be achieved by means of mechanical pumping
where the mechanical feature is installed with
adequate holding tanks and an alternative
back up power source.
Sloping sites S18.1 Buildings and associated accessways Not Applicable
O18 Development on sloping sites— are not constructed on land with a slope
a) is responsive to the natural topography of the site and minimises cut greater than 1 in 4 (25%); AND
and fill; S18.2 Buildings are of split level design that
b) does not visually dominate the hill slope or interrupt the skyline; step down the slope or have a suspended floor
c) is integrated with the natural site characteristics including construction; AND
vegetation; and S18.3 Cut or fill is less than 2m in depth;
d) for Multiple housing, takes the form of small separate buildings; AND
S18.4 The distance between the ground and
AND the lowest part of the floor of the building does
O19 On sites which are visible from the major road network, areas of not exceed 3m to avoid large under building
public open space, the Noosa River or the beaches new buildings and areas; AND
structures including outbuildings, are designed so as not to dominate S18.5 Buildings present no more than 3
or detract from the scenic and environmental qualities of the site and storeys at any one point.
its setting. S19.1 No solution provided
Roof form S20.1 With the exception of buildings within Complies
O20 Rooflines— the Industry Zone, the main roof of the building The proposed duplex has roofs with a roof
a) contribute positively to the local skyline; has a roof pitch no less than 5 degrees and pitch of 6% and 8%. For more information
b) complement the character of the locality; has minimum 600mm eaves to at least 75% of refer to the Building Plan attached in
CadCon Surveying & Town Planning
Page 6 of 10
See the original