Council archive · source document
IDASForm6-TreeRemoval-030413 · OPW13/0269
Attached to the e-mail Development Application for permit to damage vegetation - OPW13/0269.
changes in surfacing material. Applications for operational work involving stormwater drainage Drawings showing: existing and proposed contours drainage locations, diameters and class of pipe, open drains and easements manhole location, chainage and offset or co-ordinates and inlet and outlet invert levels inlet pit locations, chainage and offset or co-ordinates and invert and kerb levels. C] Confirmed irc} Not applicable Applications for operational work involving water reticulation Drawings showing: kerb lines or edge of pavement where kerb is not constructed location and levels of other utility services where affected by water reticulation works pipe diameter, type of pipe and pipe alignment water main alignments water supply pump station details (if applicable) minor reservoir details (if applicable) conduits location of valves and fire hydrants location of house connections (if applicable) location of bench marks and reference pegs. C Confirmed | Not applicable Applications for operational work involving sewerage reticulation Drawings showing: location of all existing and proposed services location of all existing and proposed sewer lines and manhole locations location of all house connection branches kerb lines or edge of pavement where kerb is not constructed chainages design sewer invert levels design top of manhole levels type of manhole and manhole cover pipe diameter, type of pipe and pipe alignment location of house connections (if applicable) sewer pump station details (if applicable). C Confirmed | Not applicable Applications for operational work involving street lighting Drawings showing: location of all light poles and service conduits location of all other cross road conduits type of wattage and lighting any traffic calming devices additional plans for roundabouts and major roads (if applicable) details of any variations to normal alignment details of lighting levels. CL Confirmed EC Not applicable Applications for operational work involving public utility services Drawings showing: any existing light poles and power poles any existing underground services details of proposed services alternation to existing services. | Confirmed LC] Not applicable IDAS form 6—Building or operational work assessable against a planning scheme Version 2.0 17 December 2012
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
IDASForm6-TreeRemoval-030413.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.