Skip to the record
Trusted by locals. Built for Noosa.

Original source · versioned page text

Site Investigation Report

of 11

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

The soil samples hand collected and classified on site were assessed as having low to
negligible plasticity, therefore laboratory testing was considered unnecessary.

The expected surface movement (Ys), due to seasonal moisture changes in the soil
encountered, is as follows

 

Ys Value = 0-20mm

 

 

 

 

 

 

 

 

 

 

Predicted Surface Movement Class
Ys= < 20 mm S
Ys=>20-< 40mm M
Ys => 40-< 60 mm Hl
Ys => 60-< 75 mm H2
Ys=>75mm E
Problem sites P

 

 

 

 

Note: The proximity of trees and their effect on foundations should be considered when
‘determining specific engineering assessments, and for foundation/footing design.
Appendix B of AS 2870-2011 indicates that to reduce, but not eliminate, the possibility of
damage to the footings, trees should be restricted to the following distance from the
building (where rows or groups of trees are present the distance nominated below must

' be increased, and similarly the Ys Value listed above may need to be increased) : 75% of
the mature tree height, for class “M” sites, 100% of the mature tree height, for class
“HI” sites,.and 150% of the mature tree height, for class “E” sites.

Note: This classification above has been derived from test work performed on the soil
profile encountered on the day of our fieldwork. Any further filling of the site or
excavation into the soil profile, may result in a different classification.

Temporary Excavations.

Where temporary excavations are performed for footing or services up to 600mm
deep, natural soils may have minor or no stability problems, however deeper
excavations have a possibility of collapse more readily and shoring of vertical
excavation may be required. Where an existing excavation has been filled with
uncontrolled fill, all locations above a line 30 degrees for sands and 45 degrees for
clays above the horizontal may be unstable and may not support any structure — see
attached critical depth line diagram.

Existing Services.

We were not informed of any existing service line excavations and no existing service
line excavations were identified within or immediately adjacent to the proposed house
site.

 

Unearthed Geotechnical P/L. 4 Site Investigation Report 023-276
Log in to download the original file

Site Investigation Report.pdf · 4.4 MB (large file)