Skip to the record
NoosaWatch™: The source of truth.

Original source · versioned page text

Approved Plans OPW26 0055

of 2

Plans and drawings: the text below has words only, no drawings.

Log in to see the plans as drawn
            NOOSA COUNCIL
            APPROVED PLAN
                                                                                                                                                                                                                   Ke
          OPW26/0055 8 JUL 2026                                                                                                                                                                                       rb
                                                                                                                                                                                                                                                                                                                     2 New Kerb adaptors as per RSD-201
                                                                                                                           6.0
                                                                                                                                                                                                                 5.5                                                                                                                                                  LINDSAY CONSULTING PTY
                                                                                                                                                                                                                                                                                                                                                                                         LTD




                                                                                                                                                                                                                                                                                            3
                                                                                                                                                                                                                                                                                       15
                                                                                                                                                                                                                                                                                     5.
                                                                                                                                                                                                                                                                                   IL
                                                                                                                             Sealed control pit                                                                                                                        nt
                                                                                                                                                                                                                                                                  radie
                                                                                                                                with bolted lid                                                                                                                %G




                                                                                                                                                                                                                                                                                            projected boundary
                                                                                                                                                                                                                                                            0.5
                                                                                                                                                                                                                                                       e-
                                                                                                                             Approx SL 5.550                                                                                                        pip
                                                                                                                                                                                                                                               N8
                                                                                                                                                                                                                                             CS
                                                     Approx SL 5.550                                                                  IL 5.218                                                                                        00
                                                                                                                                                                                                                                           PV
                                                                                                                                                                                                                                                                      T      5.0
                                                                                                                                                                                                                                .D
                                                                                                                                                                                                                                  ia 1                             CU
                                                                                                                                                                                                                              No                                         L
                                                             IL 5.068                                                                                                                                                  Ne
                                                                                                                                                                                                                         w2                                          FIL


                                                                                                                                                                                                                                           20.567


                                                                                                                                          New Dia 150 PVC SN8 pipe 1% gradient



                                   Existing 2 No. Dia 100 PVC
                             downpipes to connect into new line


                                                                                                                                                                                                                                                                                                                            New Dia 150 PVC SN8 pipe

                  REFER PAGE F26 FOR
                                                                                                                                                                                                                                                                                                                                 ALL IMPERMEABLE
                  CAPTIVE PIPE HYDRAULIC                                                                                                                                                                                             4.5                                                                                         SURFACES TO REMAIN AS
                  CALCULATIONS
                                                                                                                                                                                                                                                                                                                                 SHEET FLOW
                                                                                                                           FI T
                                                                                                                               CU
                                                                                                                             LL




                                                                                                                                         100SQM Roof Area - Front DP catchment
                CAPTIVE PIPE RELEASE CALCULATION                                                                                               4 No. Dia 100 PVC Downpipes
                                                                                                                                                                                                                                                                                                                            Existing 2 No. Dia 100 PVC
                Dia 150 PVC captive pipe to empty into lower rubble pit.                                                                                                                                                                                                                                                    downpipes to connect into new line
                Total pipework lenght 50m.
                                                                                 23.665




                                                                                                                                                                                                                                                                                                   4.0
                Total Volume =         Area of pipe x length                                                                                      EXISTING RESIDENCE
                                       0.0176sqm x 50m
                                                                                    New Dia 150 PVC SN8 pipe 1% gradient




                                       0.8835cbm

                Design Voids to rubble pit - 50%                                                                                                                         FFL 5325
                                                                                                                                                                         PAD 4925
                                                                                                                                                                Nominated on Arch plans. Plumber to
                Required Pit Size to empty pipe = 0.8835 / 0.5                                                                                                  confirm As-constructed levels prior to
                                                1.77cbm Overall Size                                                                                            construction                                                                                                                                                     Existing 3000lt Min Detention tank
                Recommended Pit Size - 0.5m wide x 0.5m deep x                                                                                                                                                                                                                                                                   to be abandoned
                                          7.08m Long
                                                                                                                                                                       155SQM Roof Area - Rear DP catchment                                                                                                                      Top of Downpipe - Approx RL 8.325




                                                                                                                                                                                                                                                                                   23.665
                                                                                                                                                                            6 No. Dia 100 PVC Downpipes
                                        IL 4.730 at slow release point
                                                                                                                                                                                                                                                                                                                                Start of drainage line - IL 5.100
                                 Slow release Dia 25mm PVC Conduit
                                    from IL of new drainage pipe to pit
                                                                                                                                                                                  New Dia 150 PVC SN8 pipe 1% gradient                                                                             3.5
                              Existing Sewer MH                                                                                                        Emt B SP260161                                       (Sewer Easement)
                                    Lid level 3.86                                                                                                                                                                                                                          S
                                                                                                                                                                                                         Existing Dia 150 Sewer Main
                                           IL 2.57                                                                                                                                                                                                                                                3.3
                                                                                                                                                                                                                                                                                                     9           5




                         Captive pipe release drainage pit only.          Connect all existing downpipes to                                                                                                      Existing Sewer MH                                                                                            Existing outlet pipe to be abandoned
                     500mm wide x 500mm deep x 7080mm long                    new drainage pipe hung from                                                                                                              Lid level 3.57
                            drainage rubble pit. SL 3.85 IL 3.25           existing blockwork/concrete slab                                                                                                                   IL 2.45

Document Set ID: 24846323
Version: 1, Version Date: 08/06/2026
Log in to download the original file

Approved Plans OPW26 0055.pdf · 418 KB (small file)

Full text of the other 1 page

Page 2

                                                                                                                                                                                                                                                                   NOOSA COUNCIL
                                                                                                                                                                                                                                                                   APPROVED PLAN
                                   LEVEL 1 PITCH                                                                                                                                                                                                                 OPW26/0055 8 JUL 2026
                                       R.L. 11165
                                     LEVEL 1 FCL
                                       R.L. 11135                                                                                                                                                                                                                                        LINDSAY CONSULTING PTY
                                                                                                                                                                                                                                                                                                            LTD

                                 LEVEL 1 JOINERY
                                                                                                    W                                 W                                 W
                                        R.L. 10825                                                 024                               023                               022                                                        W
                                                                                                                                                                                                     W
                                                                                                                                                                                                    021                          056



                                      LEVEL 1 SFL
                                         R.L. 8425                                                                                                                                                  Connect all existing Dia 100 PVC downpipes to new drainage pipe
                                   GROUND PITCH
                                       R.L. 8065
                                    GROUND FCL
                                       R.L. 8035                                                                                                                                                                                                             Lowest Point IL 5.100
                                                                                                                       W                            W
                                                                                                                      013                          012                        W                W           W                W             W
            New Dia 150 PVC SN8 drainage pipe to connect uphill to                         Lowest Point IL 4.730                                                             011              010         009              008           007

                                        lawful point of discharge

                                     GROUND SFL
                                           5325

                                     GROUND PAD                                                                                                           Existing Blocked up Waffle Slab
                                           5000                                                                                                                                                 Ground level

              Dia 25mm PVC Conduit from IL of new drainage pipe to pit
                                                                                                                                                                New Dia 150 PVC SN8 pipe 2% gradient
                                                                                                                                                                Suspended off existing concrete/blockwork wall

                                                300x300 Pit & rubble pit to receive                       Captive pipe release
                                                slow release to empty captive pipe                        drainage pit only.
                                                                                                          500mm wide x 500mm deep
                                                                                                          x 7080mm long Rubble pit                       REAR ELEVATION




                                              New Dia 150 PVC SN8 pipe 2% gradient
                                                             Suspended off existing
                                                            concrete/blockwork wall


                                       Slow release Dia 25mm PVC Conduit from IL
                                                         of new drainage pipe to pit
                                                                                                   Slab FFL 5.325
                                                      Rear Boundary




                                                                      Current GL




                     Existing Dia 150 Sewer
                            approx 1.3 deep                                                              Captive pipe release drainage pit only.
                                                                                                         500mm wide x 500mm deep x 7080mm
                                                                                                         long Rubble pit


                                                                         TYPICAL SECTION




Document Set ID: 24846323