C240
C241 C242 C243
KEY MAP
108
28 27 26
SP176968 SP176968 SP176968 IT IS THE RESPONSIBILITY OF THE
CONTRACTOR TO CONTACT THE RELEVANT
AUTHORITIES TO CONFIRM THE LOCATION OF
ALL EXISTING SERVICES PRIOR TO THE
COMMENCEMENT OF EXCAVATION
109
1
111
X2
EXISTING DRAINAGE
EASEMENT
4m
1.2m
EMT
RP BDY
LANDSACPE BUFFER
EXISTING TREE
5m WIDE
5.225m
CH 100
TO BE REMOVED
CH 60
CH 80
REFER ROAD 1 DETAIL PLAN - SHEET 1 FOR CONTINUATION
112
SM3 KERB
REFER ROAD 1 DETAIL PLAN - SHEET 3 FOR CONTINUATION
3m LEGEND
ROAD 1 PROPOSED ASPHALT ROAD
108
PROPOSED CONCRETE FOOTPATH 125mm THICK
18m
1.5m 6m 1.5m SL72 MESH 32MPa REFER C260 FOR DETAILS
PROPOSED CONCRETE DRIVEWAY 175mm THICK
3m
3 2
A 1.5m 6.3m 6.3m 1.5m A SL82 MESH 32MPa REFER C260 FOR DETAILS
600 CHANNEL 600 CHANNEL
BIORETENTION BASIN FILTER SURFACE
109
1.8m
M1 K&C LANDSCAPE BUFFER REFER LANDSCAPE PLANS
2.5m
FOR DETAILS
PROPOSED STORMWATER DRAINAGE
1.27m
SM3 KERB SM3 KERB PROPOSED SEWER MAIN
PROPOSED WATER MAIN
EXISTING STORMWATER DRAINAGE
2m
110
EXISTING WATER MAIN
EXISTING COMMUNICATIONS CABLES
1m
RP BDY
EXISTING UNDERGROUND ELECTRICAL
1m
1m
1
PROPOSED ASPHALT 11 EXISTING OVERHEAD ELECTRICAL
CARPARKING PROPOSED 6m WIDE TYPE A
1m PROPOSED 2m WIDE CONCRETE DRIVEWAY TO INTERFACE / CHANGE OF GRADE
CONCRETE FOOTPATH LOT 2 IN ACCORDANCE WITH 1
2 1 EXISTING SITE BOUNDARY
GENERALLY IN ACCORDANCE IPWEA STD DRG RS-102 D
C C
WITH IPWEA STD DRG RS-065 EXISTING TREES
RESERVE PROPOSED 900x600 LOT 2
FIELD INLET FOR LOT 2 10
STW CONNECTION DESIGN SURFACE CONTOURS (250mm INTERVALS)
PROPOSED 900x900 FIELD
10 EXISTING SURFACE CONTOURS (250mm INTERVALS)
INLET TO CAPTURE 2
RUNOFF FROM RESERVE 11
SCALE 1:100 (A1) - 1:200 (A3)
Check all dimensions before commencement of work.
Check Site boundary dimensions from the Title plans
Check Building Boundary clearances by set out.
Notwithstanding the information supplied on this drawing,
the location, depth and extent of underground or overhead
services are to be confirmed and protected on site by the
contractor prior to commencement of works.
Approved
Checked - CT
Consulting Civil & Drawing title - Project - COMMUNITY AFFORDABLE Site - Project No. 233467 Sheet No. C241
Design - SK Drawn - SK Structural Engineers ROAD 1 DETAIL PLAN - SHEET 2 HOUSING DEVELOPMENT 62 LAKE MACDONALD DRIVE, Digital Ref :
C240-C243 ROAD 1 DETAIL
PLANS Issue : A
Scales - AS SHOWN Project Management 124 DUPORTH AVENUE Ph (07) 5443 7777 Client -
NOOSA COUNCIL COOROY This Document is copyright and shall not be copied
ASSOCIATES PTY LTD PO BOX 16 Fax (07) 5443 7577 without written approval, nor shall it be used except
Document Stage - APPROVAL
A 10/01/24 ISSUE FOR CLIENT REVIEW SK
& Planning MAROOCHYDORE QLD 4558
for the Development and the Site Specified.
Issue Date Description By E-MAIL: [email protected]
c:\12dS\data\12DSERVER\233467_2957\DWG Covey\OPW\Uncontrolled\C240-C243 ROAD 1 DETAIL PLANS.dwg Plot 7 June 2024 - 11:05 AM
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix H Traffic Impact Assessment.pdfRelated documentApplication case desk ↗
About this file
- File size
- 13.3 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.