Resend{8- 7-06312:24PM;
161 7 4794162 # 7/7 8
* 18/07/2005 12:39 97-54740981 GLOBAL TESTING PAGE 685/285
GLOBAL TESTING
NATA AGGREDITED LABORATORY 1793
UNIT 6/3 COMMERCE CT. NOOSAVILLE.
PHONE/FAX 0754 740900.
THE ONLY NAME IN SOILS
DYNAMIC CONE PENETROMETER REPORT
CLIENT: N.C Oliver Pty Ltd AUTHORISED BY: J.F &P
PROJECT: Proposed Sewer Alignment, DATE TESTED: 30/06/06
128-132 Gympie Terrace,
Noosaville. JOB No. 06/0637
BLOWS PER 100mm
DEPTH(mm) | PN2 | DEPTH(mm) | PN2 | DEPTH(mm)
00-4100 1 1500- 1600 3 3000-3100
100- 200 2 1600- 1700 3 3100-3200
200-300 ‘2 1700- 1800 3 2200-3300
300- 400 4 1800-1900 4 3300-3400
400- 500 4 1900-2000 3 3400- 3500
500- 600 3 2000. 2400 4 3500- 3600
600-700 4 2100- 2200 4 3600- 3700
700- 800 2 2200- 2300 5 3700- 3800
800-900 4 2300- 2400 4 3800- 3900
900-1000 4 2400- 2500 4 3900- 4000
1000- 1100 2 2500- 2600 13 .
1100-1200 2 2600- 2700 31
1200- 1300 3 2700-2800 >40
1300- 1400 2 2800- 2800 ‘
1400- 1500 3 2900- 3000
acogrdance mith ts terns of sccreditatign
TRIS REPORT SBALL NOT BE REPRODUCED EXCEPT ik
FULL, TTS REPORT, AS DATED. SUPERSEDES ALL fo
PREVIOUSLY ISUBO REPORTS a
Lf { g ,
AUTHORISED SIGNATORY... "Sedo DATE TESTED.247/%..
f
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
06/0159 - Plans for final approval [As Published]Related documentApplication case desk ↗
About this file
- File size
- 1.1 MB (small file)
- File type
No other editions are linked here.