Attachment 2 - Landscape Plans
Plans and drawings: the text below has words only, no drawings.
Determining the Radius of the TPZ (Tree Protection Zone)
· DBH (Diameter at Breast Height) - nominal trunk diameter at 1.4m above ground level
· TPZ should not be less than 2m nor greater than 15m (except where crown protection is required)
· TPZ = DBH X 12
· TPZ of palms, other monocots, cycads and tree ferns should not be less than 1m
· Variations and encroachments to the TPZ in accordance with AS 4970
3x Tube Ø
Tubestock plant as specified
Fluorescent orange 5.5k.g
Form shallow saucer shaped depression
barrier fencing mesh secured
around plant base
/ tied 100mm below top of star Plant pit 2x width of respective pot.
Measurement 2x pot Ø Shrub / groundcover / tufty
pickets at 300mm centres Scarify all pit walls and bottom, typ.
taken for DBH grass plant species per plan
Yellow plastic capped Pot Ø
100mm deep organic mulch as specified,
Fencing
star pickets minimum 50mm clear of plant stem
painted yellow Backfill plant pit with specified 100mm deep and settled organic
Vegetation to 1200mm
1.4m
topsoil, avoid compaction, typ. mulch as specified, keep minimum
be protected Ameliorated site topsoil as specified, avoid
50mm from plant stem. Form shallow
Ground line compaction, typical
dish drain to base of plant, typ.
Crown DBH Garden topsoil as specified,
600mm
TPZ avoid compaction, typ.
150mm deep cultivated subgrade, typical
NOTES:
100mm, typ.
· Protective fencing to be installed around the TPZ to the commencement of any site works
Slow release fertiliser as specified. Slow release fertiliser as specified. Use
· Protective fencing identifying the TPZ, to be visibly signed within the development site. Lettering to comply with
Use phosphorus free tablets for phosphorus free tablets for Banksia,
AS 1319. 2x rootball depth, typ.
Banksia, Callistemon and Grevillea Callistemon and Grevillea species.
· Fence posts and supports to have a diameter greater than 20mm, located clear of roots
· Where tree protection fencing cannot be installed, trunk, branch and ground protection as specified by the project species.
Arborist in accordance with AS 4970 150mm, typ. 150mm deep cultivated Subgrade
· Within TPZ, mulch to a depth of 50-100mm only for disturbed land subgrade, typ.
· Maintenance of TPZ includes regular monitoring of soil moisture levels and weed removal by hand and controlled by
appropriate use of herbicide Existing subgrade, typ.
· TPZs to be monitored, inspected and certified by the project Arborist
· Removal of tree protection measures at practical completion or as indicated by the project Arborist
1 Tree and Vegetation Protection Detail N.T.S. 3 Potted Shrub, Groundcover Planting 5 Tubestock Planting N.T.S.
LD3 Typical Detail LD3 Typical Section Detail N.T.S. LD3 Typical Section
Notes
· Refer to architect's plans for planter wall heights/widths/materials and podium planter bed widths.
· Refer to hydraulic engineer's plans for planter drainage and irrigation designs, and sealing.
Note:
· Refer to irrigation designer's plans for irrigation system design.
The top of the turf's thatch should be 10mm below any hard surface low point(s) to allow surface drainage.
· Water proofing and independent certification of water proof membrane by others.
· Refer to Finishes Schedule for product specifications and Planting Schedule for plant selections.
600mm
typical
Plant per plan and Plan Schedule
Drip irrigation emitter and tube
Slotted inspection grate, do not glue
Varies,
Mulch as specified, 100mm deep settled, 50mm from plant stem, typ. refer
Turf as specified 100mmØ uPVC slotted drainage / inspection pipe - 1m from tree rootball, typ. Plans
1) Planter wall, typ.
150mm Topsoil as specified
2) Waterproofing as specified to all interior planter wall surfaces, typ.
Steel Edging as specified 3) Protection board as specified
4) Geo-textile membrane as specified
Drainage cell as specified
100mm mulch as specified 50mmØ pvc drip irrigation conduit
Tapered Edging Stake as specified
300mm Topsoil as specified Proprietary podium drainage unit and carry-off pipe by builder
150mm cultivated subgrade, typ. Podium slab bottom to slope minimum 3% to low point, typ.
Existing subgrade Podium soil as specified Road Back of kerb or hardstand Turf Roll, typical
2 Steel Garden Edge N.T.S. 4 Podium Planter 1:30 6 Turfing
LD3 Typical Detail LD3 Typical Section LD3 Typical Plan Detail N.T.S.
NOTES:
This plan is Copyrighted © by Bird Landscape Design (Brian Bird - AILA RLA #1736).
Landscape Operational Works Package Project: BIRD LANDSCAPE DESIGN
Any reproduction or unauthorized use without written consent from Job No: 2543 Proposed Townhome Development Landscape Architecture Urban Design Land Planning
Bird Landscape Design is strictly prohibited. 4 Ventura Street, Sunrise Beach, QLD 3 Vector Place, Little Mountain, QLD 4551 Australia
13.6.25 C For Application BB BB Do not scale from PDF plans. M: +614 7705 5222
13.6.25 B For Application BB BB
LD3 Details E: [email protected]
11.6.25 A For Application BB BB
Sheet Title Sheet 3 of 5 Client: Alex Comino W: birdgolfdesign.com
DATE ISSUE DESCRIPTION DRAWN CKD