          Notes for Construction & Maintenance of Timber Decks:

          Builder to adhere to BCA Part 3.10.6 & to Manufactures Engineers specifications or industry standards at all times &               Timber Queensland recommend that all timber has a moisture content of 15%
          Owners to follow manufactures details for maintenance & cleaning of deck                                                           Decking boards to be fixed with 2/nails or screws & staggered or offset along the joists. Holes at ends of boards to be
          All timber posts to be naturally durable Class 1 or 2 above ground or softwoods H3 treated if supported on bracket if in           drilled holes to be 80% of nail diameter & 12mm from ends of boards. Nails & screws to finish flush with top of boards (Not
          ground to be H5 Treated soft or hardwood.                                                                                          Punched). Nails or screws to be hot dipped galvanized or stainless steel. Stainless Steel to be used within 900 mm of
          Recommend brackets or supports be used & Bitumen paint be applied to the top 200 mm of bracket in the concrete.                    pools
          Posts to have a Minimum 75 mm clearance from the base of the post to footing or slab & post to be 10 mm above cross                All Framing Anchors, Fixing Plates, Nailing Plates, Joist hangers to be Galvanised Minimum or Stainless Steel where
          member of bracket. End grain of post to be sealed prior to erecting.                                                               Construction within 2.0 km radius of open coastal areas
          Top of concrete pad footing to be mounded to fall away from support to prevent water from ponding                                  Ends of boards to be slightly undercut at joints. Gaps between decking boards to be min 3 mm to 5 mm
          Bearers, Hardwood to be H3 treated if less than 400 mm above ground H4 for touching ground H5 for in ground.                       (Check with supplier Gaps range with different Types of timbers)
          Joists as bearers depending on ground clearance. Joists to have Malthoid strip or an, approved proprietary joist protection        Decking boards to be fully sealed (Oiled, Stained, Painted etc.) prior to fixing.
          system, fixed to top of joists. Softwood & Engineered manufactured timbers bearers & joists to be H3 min treated at all            Recommend a light coloured sealer, with UV protection and a fungicide to be used
          times. Approved connectors be used for treated timbers & location.
          Recommend hot dip galvanized or stainless steel connectors & fixings be used at all times. Especially where inspections            Maintenance & inspection of deck by Owner is to be carried out regularly
          are not possible deck is to close to ground or decking to be screwed in place to allow for easy removal to inspect sub-floor       Sweep or blow, leaf or other debris off deck. Hosing or use of water to be avoided. Keep the gaps between decking boards
          for any issues                                                                                                                     clear of dirt & debris.
                                                                                                                                             Reseal decking boards when required by manufactures recommendations
                                                                                                                                             Inspect all connections for corrosion or movement regularly (Twice Yearly)
                                                                                                                                             Pot plants to be on stands with a drip tray underneath & moved around regularly to prevent uneven weathering of the deck
                                                                                     600                                                     Accolade Building Designs recommends that Builder & Home Owners read Domestic Deck Design Guide                               600
                                                                                                                                             Available on line www.timber.net.au


                                                                                                                                                                                                                                                                                        Custom Orb Roof sheets
                                                                                                                                                                                                                                                                                        Fixed to Manufactures details for N3 Wind Classification
      Approved type roof Trusses to Manufacturers @ 900 Ctrs                                                                                                 5°                                                                                                                         Approved type roof battens @ 900 Ctrs
      30 mm Galv looped strap or 2/Framing anchors (Triple Grips                                                                                                                                                                                                                        Fixed to Manufacturers details for N3 Wind Classification
      4/30 mm nails per leg)
                                                                                                                                                                                                                                                                                        Approved type metal gutter guard
                                                                                                                                                                                                                                                                                        as required by BAL



                                                                                                                                                                                                                                                                                        Colorbond metal Fascia & Gutter
      RB1: Roof beam 2/M12 bolts to posts
      Manufactured beams to be protected                                                                                                                                                                                                                                                Approved type 6 mm FC Sheet to Soffit
      from weather as per Manufacturers details and BAL Requirements                                                                                                                                                                                                                    Top plates 2/90x45 MGP12


      C2: Hardwood Timber Posts Approved type timber for BAL Rating




                                                                                                                                                                                                                              Ceiling Hgt 2700
                                                                                                                                                        W3                                                   W4                                        W5




                                                                                                                                                                                                                                                            2400
                                                                                                                                                                                                                                                                                        Tie-down 12 mm rods from subfloor to top plates
      Hardwood Timber decking boards to joists                                                                                                                                                                                                                                          Studs 90x35 MGP 12 @ 450 Ctrs
      Approved type timber for BAL Rating
                                                                                                                                                                                                                                                                                        Cladding to comply with BAL supplied by
                                                                                                                                                                                                                                                                                        an Approved Qualified person
      J2: Hardwood Timber Joists @ 450 Ctrs 1/framing anchor 4/30 mm nails per leg
      Joist protector strips to top of Joists Approved type timber for BAL Rating                                                                                                                                                                                                       Bottom Plates 90x45 MGP12

                                                                                                                                                                                                                                                                                        J1: Joists at 450 Ctrs 1/Framing anchor 4/30 mm nails peer leg
                                                                                                                                                                                                                                                                                        @ Joists under outer walls
                                                                                                Less than 1000




      C2: Hardwood Timber Bearers Approved type timber for BAL Rating
      2/M12 bolts to Posts
                                                                                                                                                                                                                                                                                        B1: Bearers 2/M12 bolts to C1




                                                                                                                                                                                                   Min 400
      Pryda PSQ600100/12
      Post support bracket 2/M12 bolts to posts
                                                                                                                                                                                                                                                                                        C1: Galv SHS posts to Engineers details
      N12 Cranked through support 1000 mm in length
                                                                                                                                                                                                                                                                                        Bitumen paint to Posts min top 200 mm in concrete
                                                                                                                                                                                                                                                                                        Concrete pad footings to Engineers details




                                                                                                                                Ground Under Floor & Decks to be have ALL vegetation removed and be Graded so Groundwater Does Not Pond Under Floors



                                                                                                                                                                                Section A
                                                                                                                                                                     A            1 : 50
                                                                                                                                                                                                                                                                                                      Engineers Details to Take
                                                                                                                                                                                                                                                                                                      Precedence Over Shown Details

      Client: Scott Stewart                                            Address: 797 Ringtail Creek Rd. Pomona                            Noosa Shire Council                                                                                                Mobile: 0407 693 018        Date     25/10/2021 7:43:19 AM
                                                                                                                                                                                  ACCOLADE Building Designs                                                                             Drawn by; S.Horn Drawn for A3 Sheet
      RPD: Lot 4 on RP 213871                                      Site Area : 34073 m²                          Wind Classification N3                                                     Proprietor: Steven Horn                                  Email: [email protected]
                                                                                                                                                                                                                                                                                                        Project Number                         0521SS
     Proposed
Document            Residence SHS & Timber Posts , Timber Framed, Sheet Roof
         Set ID: 21731676                                                                                                                                                                    QBSA Lic. 54806                                         Issue Date:           25 - OCTOBER -2021           Scale 1 : 50          Sheet No. 4          of 9
Version: 1, Version Date: 14/12/2021
Log in to download the original file

Approved Plans - MCU21_0221.pdf · 9.6 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.