Required 32.5 kN Supplied 33.9kN
10.6 kN 10.6 kN
1.8 (FC) 1.8 (FC)
W6 W7 RB1 W8 W9 RB1
Door Schedule
0.9 (FC)
5.3 kN
D3
1.8 (FC)
10.6 kN
Mark Height Width Comments Location Lintel Jamb Studs
W5
5.3 kN D1 2100 4320 Bifolds Kitchen Engineers details Engineers
D2 2100 1800 Alum Slider Kitchen 130x42 LVL 15 2
1.8 (FC)
0.9 (FC)
10.6 kN
D3 2040 820 External Laundry 90x45 MGP12 2
0.9 (FC)
5.3 kN
D4 2100 3200 Alum Stacker Bed 1 200x42 LVL 15 3
Required 60.2 kN Supplied 60.3kN
W10
D2
W4
1.8 (FC)
10.6 kN
1.2 (FC)
6.3 kN
DIRECTION A
Window Schedule
0.9 (FC)
5.3 kN
Mark Height Width Comments Location Lintel Jamb Studs
D1
W1 1800 1500 Alum Slider/Trans Bed 1 130x42 LVL15 2
W2 1800 1500 Alum Slider/Trans Bed 1 130x42 LVL15 2
W3
D4
Roof Braced to Manufacturers details W3 1200 1800 Alum Slider Bed 1 130x42 LVL15 2
W4 1200 1800 Alum Slider WIR 130x42 LVL15 2
W5 1200 1800 Alum Slider ENS 130x42 LVL15 2
1.2 (FC)
6.3 kN
W6 1200 900 Alum Slider ENS 90x45 MGP12 2
W7 1200 900 Alum Slider ENS 90x45 MGP12 2
W8 1000 1500 Alum Slider Laundry 130x42 LVL15 2
W2 W1 W9 900 600 Alum Slider Powder 90x45 MGP12 2
1.4 (FC)
7.4 kN W10 1000 1500 Alum Slider Kitchen 90x45 MGP12 2
RB2 RB2
Wind Bracing determined from AS1684.2 for N3 sites Roof Beams
: 12mm Tie-down rods @ 1200 crs max & 100 from Openings & corners RB1: 240x58 Smart LVL 15
RB2: 200x58 Smart LVL 15 Cont/Span
1.0 (VB) Denotes 6mm thick Villa board fixed to Manufactures detail
to supply 5.3 kN/m as per Hardies Bracing Manual
Bracing Layout
1 1 : 100
Client: Scott Stewart Address: 797 Ringtail Creek Rd. Pomona Noosa Shire Council Mobile: 0407 693 018 Date 25/10/2021 7:43:20 AM
ACCOLADE Building Designs Drawn by; S.Horn Drawn for A3 Sheet
RPD: Lot 4 on RP 213871 Site Area : 34073 m² Wind Classification N3 Proprietor: Steven Horn Email: [email protected]
Project Number 0521SS
Proposed
Document Residence SHS & Timber Posts , Timber Framed, Sheet Roof
Set ID: 21731676 QBSA Lic. 54806 Issue Date: 25 - OCTOBER -2021 Scale 1 : 100 Sheet No. 6 of 9
Version: 1, Version Date: 14/12/2021
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.