Council archive · source document
51993.766.2 Request to change existing approval (TPC 2613)
1-course bondbeam
2-N12 bars
grout fill concepts
331OUB 46.2
steel beam
& designs
ABN 80130019288
BSA Uc. No. 61374
VIEW-X PH; 0410 627 589
PH: 0438 945 935
Email: [email protected]
N12 bars, 750 long 200 series block wall
1 ALL CONSTRUCTION TO BE IN
at max. 400 crs, N12 bars at 400 max. crs ACCORDANCE WITH THE
p n A n+. , p!11! M1!!.!n AM
epoxyed 125 Mina
WIND CLASS (N3 ?
into scabbled face 200 series block wall RELEVANT AUS STOS. QLD DEV.
N12 bars at 400 max, crs 2-M16 bolts CODE, RELEVANT LOCAL GOVT.
of ext. slab-
grout all cores cast 600 into f BY-LAWS.
blockwork 1
2 BUILDER OR CONTRACTOR IS
TO VERIFY ALL DIMENSIONS &
DETAILS BEFORE THE
COMMENCEMENT OF ANY WORK.
VIEW-X 3 ALL DIMENSIONS SHOWN IN
MILLIMETRES U.N.O.
DO NOT SCALE OFF DRAWING.
NOTES:
ceilinght 2400 Min.
SECTION 300 PFC
joinery ht 2100
steel beam
fix to laminated beam REV.I DE9 RIP10 1 BY I DALE
batten out around
2-M12 bolts each end THESE DESIGNS AND PLANS ARE COPYRIGHT
beam, box in with AND ARE NOT TO BE USED OR REPRODUCED
then 1-M12 bolt at WHOLLY OR IN PART OR TO BE USED ON
plasterboard sheet, ANY PROJECT WITHOUT THE WRITTEN
600 Max, crs staggered PERMISSION OF PJ CONCEPTS & DESIGNS PTY.
paint finish LTD.
0
0
300 PFC
steel beam DETAIL-1 CLIENT
P & J WHITE
New trusses, roof sheet.
89x89x6.0 SHS I "',-10 top plate Pitch to match existing
post (in wait frame) -I 6cfw to 89 SHS PROJECT
2-M16 bolts 6 cleat plate
6cfw to top EXTENSIONS TO
to 300 PFC UNIT 2
10 base plate flange 310 beam
at 900 crs,1-M12 SOLWAY DRIVE
6cfw to 89 SHS SUNSHINE BEACH
4-M12 cranked bolts saw cut existing slab bolt to new truss
cast 300 into footing to place new footing.
provide ceiling battens 8 web stiffener
existing slab and plasterboard lining 6cfw to 31OUB beam
to truss bottom cord. TITLE ENGINEERS
paint finish
0 SECTIONS &
0
A \ J DETAILS
New footing DATE 04.10 DRAWN PWO
300 PFC
steel beam joinery ht 2100
600 square „
SCALE: I :50, 1:20
10 cleat plate SHEET No. I I of I I
New soffit
SECTION - D 6cfw to 310UB beam
3-M16 bolts
lining.
paint finish DWG NO. REV.
to 300 PFC
DETAIL 2 09109.011
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
51993.766.2 Request to change existing approval (TPC 2613)Related documentApplication case desk ↗
About this file
- File size
- 3.2 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.