Council archive · source document
Appendix G- Environmental Noise Assessment · MCU23/0078
PO79 AO79.3
Development, including mechanical plant, vehicle manoeuvring Mechanical plant is:
and communal outdoor recreation uses: a) located at least 2 metres from side or rear property
a) do not have an adverse effect on the amenity enjoyed boundary;
by users of adjacent or nearby premises through b) where located at ground level, screened by fencing
emission of noise, light, fumes or smoke; 1.5 metres in height or dense vegetation of at least
b) do not cause unreasonable disturbance to local fauna 1.5 metres in width incorporating grouped trees
through light or smoke emissions. and shrubs with maximum separation distance of 1
metre measured from the centre of the plant;
c) where located above ground level, enclosed or
screened such that it is not visible from the
street frontage nor adjoining properties; and
d) visually integrated into the line and plane of
the building and roof design and does not project
beyond the height or width of the building when
viewed from the street and adjoining properties.
Editor’s Note— Mechanical plant includes generators,
motors, compressors and pumps such as air-conditioning or
pool equipment.
To comply with AO39.1 and AO78.2, onsite activities have been assessed against the Environmental
Protection (Noise) Policy 2008 (EPP 2008).
To comply with AO79 it is recommended all mechanical plant is acoustically screened from nearby sensitive
receivers.
The Dual Occupancy and Multiple Dwelling Code specifies relevant noise requirements as presented in Table
5.
Table 5: Dual Occupancy and Multiple Dwelling Code – Relevant to Noise for this development
Performance Outcome Acceptable Outcome
PO5 AO5
Development is designed to minimise noise carrying Bedroom windows are at least 3 metres away from shared
between dwelling units or accommodation units by locating driveways, car parking areas, mechanical plant, refuse and
noise sensitive spaces such as bedrooms away from noise recycling areas, vents and exhausts.
generating areas of the development, such as car parking
areas or mechanical plant and equipment or recreational
facilities.
PO6 AO6.4
Where dwellings form part of a mixed use development, the Dwellings are designed to incorporate suitable noise attenuation
development provides residents with reasonable privacy and privacy measures to reduce amenity impacts from business
and security. uses.
It is recommended that the design of the development complies with Acceptable Outcome AO5 for
minimum residential facade setbacks (3m) from shared driveways, car parking areas, mechanical plant,
refuse and recycling areas, vents and exhausts.
Site: Eenie Creek Road, Noosaville 13
Reference: 22BRA0078 R01_2
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records