Council archive · source document
Appendix G- Environmental Noise Assessment · MCU23/0078
ii. Day and Evening operation (7am – 10pm), 2 speakers both operating at a maximum Sound
Pressure Level of 100dB(A) @1m.
iii. Night-time operation (10pm – 2am), 2 speakers both operating at a maximum Sound Pressure
Level of 90dB(A) @1m.
d. Any speed humps should be bitumen, concrete (as part of the slab) or rubber, not metal.
e. Any grates or other protective covers in the car parking area should be rigidly fixed in position to
eliminate clanging and be maintained.
7.3 Mechanical Plant Noise
Because detailed plant selections are not available at this stage, it is not possible to carry out a detailed
examination of the noise control measures that may be required to achieve the noise targets for mechanical
plant.
To comply with AO79 it is recommended all mechanical plant is acoustically screened from nearby sensitive
receivers.
A mechanical plant noise assessment should be conducted by a suitably qualified acoustic consultant once
plant selections are finalised.