Council archive · source document
Development Application Part 3 - Construction Management Plan, Floor Plans · OPW11/0335
Plans and drawings: the text below has words only, no drawings.
Very large file (10.1 MB): may take a few minutes to open.
Where Telstra owned cable crosses agricultural land, Telstra may provide a once off free on-site electronic cable location. The
Telstra Plan Services operator will provide assistance in determining whether a free on-site location is required.
Please note:
• The exact location, including depth of cables can only be verified by pot holing, which is not covered by this service.
• This service is only available to assist private rural land owners.
• This service covers one hour on-site only. Additional time can be purchased directly from the Accredited Plant Locator.
For further information including terms and conditions, please contact Telstra Plan Services on phone 1800 653 935.
PRIVACY NOTE
Your Information has been provided to Telstra by DBYD to enable Telstra to respond to your DBYD request. Telstra keeps your
information In accordance with Its privacy statement entitled "Protecting Your Privacy" which can be obtained from Telstra either by
calling 1800 039 059 or visiting our website at www.telstra.com.au/privacy
A GUIDE TO READING Leitstra PLANS Teldi Corporation Limited
ANN 33 CG17 75 S56
Exchange Cable j ointbig pit
(major cable present) (number indicating ph type)
Footway access chamber Buried cable jobitbtg pit
(can vary from 1-lid to 12-lid) (number indicating pt type)
0 Elevated cable joint
Roadway access chamber -T- (above ground joint on buried cable)
Pillar/cabinet
or Cable loop (direct buried)
(above the ground /free standing)
Above ground complex equipment
housing (eg RIM) Telstra Plant In shared ullillytrendi
Please Note: This equipment is
powered by 240V electricity.
A Aerial Cable
(above ground
PT Public telephone
Please Note: This equipment is _ Aerial cable
powered by 240V electricity. (attached to joint use pole e.g power;
Direct buried cable -SMOF-1-- Optical fibre cable direct buried
SMgleto Multiple round conduit Some examples of conduit type and size:
0 Conigurstions 1, 2, 4, 9 respectively A - Asbestos cement, P - PVC I plastic, C - Concrete,
Q oroor
P100 (Attache dtamdenotes conduit type and size) 01- Galvanised iron, E - Earthenware.
Conduit sizes nominally range from 20mm to 100mm.
P50 50mm PVC conduit
Multiple square conduit P100 100mm PVC conduit
m or or
® Contgundions 2, 4, 6 respectively Al 00 100mm asbestos cement conduit
E85 (Attadtedtaa denotes conduit We and size) E 85 85mm square earthenware conduit
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Development Application Part 3 - Construction Management Plan, Floor PlansRelated documentApplication case desk ↗
About this file
- File size
- 10.1 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.