Council archive · source document
Appendix G - Code Assessment · MCU22/0140
topography and sits within the AO23.2
landscape rather than dominating it; and On sloping sites, split level buildings with small floorplates, that
2. steps down slopes or uses suspended step down the slope are used as an alternative to standard single
floor construction, minimising cut or fill or double storey construction to minimise building bulk and
and avoiding benching of the site. benching of the sites.
Editor's note- refer to Figure 6.9.1A and Figure 6.9.1B
AO23.3
The distance between the ground level and the lowest part of the
floor of the building does not exceed 3 metres.
Earthworks and drainage
PO24 AO24 Complies.
Filling and excavation for operational works do not Filling and excavation for operational works is designed and
directly, indirectly or cumulatively cause adverse constructed to ensure overland flow and/or flooding is not
impacts external to the development site by: worsened, impeded, or otherwise diverted to adversely affect other
properties or downstream environments.
1. causing ponding of water on the site or
nearby land;
2. increasing flooding, which adversely
affects the safety or use of any land
upstream or downstream; or
3. adversely affecting the flow of water in
any overland flow path.