Original PDF page 64, section 2. The text section number identifies this passage in the reader.
BASKET
OR APPROVED EQUIVALENT
EXISTING SURFACE
REFER DETAIL ON DRG 3307
21.983
2.98
1.49
2.583
1.288
0.89%
99.512
1050(2)
111.88
267.948 E 816.458 100.672 98.459 2.214 99.512 STD MANHOLE 1/T
N 959.345 98.439 2.234 99.489 1350mm DIA
42.637
3.89
1.48
3.704
1.285
54.41
1.84%
98.708
1050(2)
310.585 E 842.920 99.667 97.655 2.012 98.708 STD MANHOLE 1A/T
N 992.777 97.635 2.032 98.685 1350mm DIA
42.779
3.20
1.48
2.843
1.278
92.32
1.08%
1050(2)
PALM LAKE WORKS PTY LTD
98.222
353.363 E 868.249 98.574 97.172 1.402 98.222 PRECAST 1050mm DIA. HEADWALL OUT/T
DESIGN SURFACE
N 1027.250 97.172 1.402 98.222
0.000 E 821.201 100.154 99.636 STD FIELD INLET 1/V
N 967.253 99.135 1.018 99.510 600x900 TYPE 1 'V' GRATE
REFER DETAIL ON DRG 3307
84.0
C 2015
2.24
1.33
0.235
0.147
55.65
1.80%
375 (2)
41.611
98.982
41.611 E 846.229 99.406 98.388 1.018 98.982 STD FIELD INLET 2/V
N 1000.496 98.313 1.093 98.943 600x900 TYPE 1 'V' GRATE
16.541
2.05
1.12
0.316
0.179
81.31
1.23%
98.878
450 (2)
58.153 E 854.759 98.895 98.109 0.786 98.885 STD FIELD INLET 3/V
V
N 1014.668 98.089 0.806 98.771 600x900 TYPE 1 'V' GRATE
www.calibreconsulting.co
7.446
1.44
1.18
0.202
0.188
0.50%
98.739
450 (2)
200.00
65.598 E 850.385 99.030 98.052 0.978 98.773 STD MANHOLE 4/V
N 1020.694 98.032 0.999 98.523 1050mm DIA
3.409
1.56
1.56
0.201
0.249
0.50%
98.497
450 (2)
200.52
69.007 E 852.898 99.011 98.015 0.996 98.497 HUMEGARD HG15/R GPT/V
N 1023.036 98.015 0.996 98.473 DN450, REFER DETAIL ON DRG
3307
PROJECT
2.980
DISCLAIMER
1.56
1.56
0.202
0.248
0.50%
98.450
450 (2)
200.00
71.987 E 854.491 98.124 98.000 0.124 98.450 CUSTOM HEADWALL OUT/V
N 1025.589 98.000 0.124 98.450
0.000 E 812.067 99.546 99.057 STD FIELD INLET 1/Y
N 1024.166 98.723 0.823 98.971 600x900 TYPE 1 'V' GRATE
85.0
Y
STAGE 3
1.46
0.73
0.058
0.029
59.67
1.68%
29.005
98.850
225 (PVC)
29.005 E 840.985 98.903 98.237 0.666 98.852 STD FIELD INLET 2/W
PALM LAKE RESORT
N 1026.417 98.162 0.741 98.787 600x900 TYPE 1 'V' GRATE
19 TRADING POST ROAD - COOROY
0.000 E 825.978 99.541 99.094 STD FIELD INLET 1/Z
N 1006.484 98.780 0.761 99.005 600x900 TYPE 1 'V' GRATE
CONSTRUCTION. USE WRITTEN DIMENSIONS ONLY, DO NOT SCALE.
85.0
ALL DIMENSIONS TO BE CHECKED ON SITE BY CONTRACTOR PRIOR TO
1.46
0.50
0.066
0.020
45.98
2.17%
24.950
98.850
PROJECT No.
Z
24.950 E 840.985 98.903 98.237 0.666 98.852 STD FIELD INLET
DRAWING TITLE
2/W
N 1026.417 98.162 0.741 98.787 600x900 TYPE 1 'V' GRATE
16-003302
11.006
1.46
0.91
0.097
0.064
1.00%
98.739
100.05
35.956 E 850.385 99.030 98.052 0.979 98.773 STD MANHOLE 4/V
225(PVC) 300 (PVC)
N 1020.694 98.032 0.999 98.523 1050mm DIA
0.000 E 859.697 98.000 98.300 FIELD INLET 1/ZZ
DRAWING No.
N 1027.973 97.240 0.760 97.727 900x900 RAISED GRATE
3306
ZZ
84.0
1.72
1.72
8.094
0.180
0.274
0.40%
97.657
250.00
450 (2)
8.094 E 867.985 98.419 97.207 1.212 97.657 PRECAST 1050mm DIA. HEADWALL OUT/ZZ
STORMWATER DRAINAGE
LONGITUDINAL SECTIONS
N 1027.991 97.207 1.212 97.657 OUTLET IN WINGWALL
1
REVISION
N.S.C. REF NO. MCU15/0111 & REC15/0031
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.