Appendix B - Code Assessment

Attached to the e-mail MCU15/0085 Development Application.

of 33

Page text shows just the words. Original shows the document exactly as it was published.

Landscaping Code
!


                                              of
                                              700mm from the road pavement (not top of
                                              kerb).
Services and utilities                        S7.1 Plant species used in landscaping               S7.1-7.6 Not Applicable
O7 All landscaping works maintain adequate    adjacent
                                                                                                   There are no electrical services and utilities that will
safe distance from services and utilities     to substations, or adjacent to or on electricity
                                                                                                   be affected by landscaping.
including substations, overhead powerlines,   transmission line easements, are less than 4m
power poles and transformers, street lamps,   high at maturity and do not encroach within 3m
stormwater catchment pits, and underground    of
services and utilities.                       a substation boundary;
                                              OR
                                              S7.2 For trees higher than 4m, trees are
                                              planted
                                              at a distance from any part of an electricity
                                              transmission line at least equal to the expected
                                              height of the tree at maturity (see Figure 14-17);
                                              AND
                                              S7.3 For power lines that connect to a
                                              premises,
                                              the height of plant species at maturity provides
                                              for
                                              a 2m clearance below the power line; (see
                                              Figure
                                              14-18)
                                              AND

                                              S7.4 Trees and large scrubs are located a
                                              minimum of—
                                              a) 5m from electricity poles and pillars;
                                              b) 4m from street lamps;
                                              c) 2m from stormwater catchment pits; and
                                              d) 2m from underground services and utilities;
                                              AND
                                              S7.5 Plants are located to enable
                                              tradespersons




!
Log in to download the original file

APPENDIX B - CODE ASSESSMENT.pdf · 569 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.