Cooroy & Lake Macdonald Locality Code
flooding of non-habitable areas; a minimum of 500mm above the modelled flood
c) ensure carparking areas can be adequately level; and
drained; c) for areas where flood modelling is not
d) ensure drainage does not adversely impact available a minimum of 500mm above the
upon other premises; and highest known flood level;
e) ensure filling or excavation does not
AND
adversely impact upon other premises by—
S14.2 Where Council infrastructure is
i. causing ponding on the site or nearby
available—
land;
a) any drainage (including buildings and
ii. increasing flooding, which adversely
yards) flows to that infrastructure; and
affects the safety or use of any land
b) the infrastructure has the capacity to
upstream and downstream; and
accept any additional loading;
iii. adversely affecting the flow of water in
AND
any overland flow path.
S14.3 Car parking and maneuvering areas are
constructed at a level that permits the parking
area to drain from the site by gravity means,
without the need for mechanical pumping; or
S14.4 Basements for residential uses have
flood immunity above the Q100 where
alternative means to mechanical pumping are
used to achieve such immunity; or
S14.5 Basements for non-residential uses have
flood immunity above the Q100 that may be
achieved by means of mechanical pumping
where the mechanical feature is installed with
adequate holding tanks and an alternative back
up power source.