Original source · versioned page text
Appendix A - Bushfire Hazard Assessment & Management Plan
Attached to the e-mail RAL20/0014 - Response to Council's Information Request - 9A Jirrima Cres, Cooroibah - Email 01 of 02.
The original of this document is very large (14.0 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawnBushfire Hazard Assessment & Management Plan v1 NCES REF: J000706 Lot 101 on SP168341 – 9a Jirrima Cres, Cooroibah 6 AUSTRALIAN STANDARD 3959:2018 CONSTRUCTION OF BUILDINGS IN BUSHFIRE PRONE AREAS (AS 3959:2018) SETBACKS The site is mapped within the Natural Hazards Overlay in the Noosa Plan 2020 (refer to Plate 13) DRAFT NOT FOR SUBMISSION PURPOSES Plate 13 – Noosa Natural Hazards Overlay map Building works within Designated Bushfire Prone Areas identified on a Bushfire Hazard Overlay Map prepared under a power of legislation triggers building design assessment under AS 3959:2018. The Standard provides minimum construction requirements for new habitable dwellings and habitable building alterations in designated Bushfire Prone Areas. The construction requirements are intended to improve the performance of buildings subjected to burning debris, radiant heat or flame contact. Building works in Designated Bushfire Prone Areas must be built to the Bushfire Attack Level (BAL) construction standard relevant to the building site as identified by the AS 3959:2018 methodology. A specific BAL assessment will be required once building plans have been progressed given the BAL relies on an accurate understanding of the final footprint of the building within the BLE and is required to be assessed against the active iteration of the Standard at the time of assessment. Based on the Plan of Development and the proposed setbacks to hazardous vegetation of 14m, it is anticipated that the future dwelling on Lot 1 will be exposed to a maximum BAL 29 Construction Standard. LEGISLATION AND OVERLAYS 6.1 Noosa Plan 2020 – Natural Hazards Overlay Code The proposed development is considered assessable development and therefore is assessable against Table 13.9 Bushfire Hazard Area of Council’s Natural Hazards Overlay Code which has been reproduced as Table 5. © 2020 25
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.