Skip to the record
For the highest quality transcripts.

Original source · versioned page text

Appendix A - Bushfire Hazard Assessment & Management Plan

Attached to the e-mail RAL20/0014 - Response to Council's Information Request - 9A Jirrima Cres, Cooroibah - Email 01 of 02.

of 35

Page text shows just the words. Original shows the document exactly as it was published.

Very large file: it may take a few minutes

The original of this document is very large (14.0 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Plans and drawings

This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).

Log in to see the plans as drawn
Bushfire Hazard Assessment & Management Plan v1                                                                                                                                                               NCES REF: J000706
Lot 101 on SP168341 – 9a Jirrima Cres, Cooroibah




Table 5 – Table 8.2.3.3 Bushfire Hazard Area Code –Noosa Plan 2020


 PERFORMANCE OUTCOMES                                            ACCEPTABLE OUTCOMES                                                       PROPOSED SOLUTION

Safety of people and property
PO1                                                             AO1.1                                                                      A01.1 This Bushfire Hazard Assessment and Management Plan has been
Development maintains the safety of people and                  Development which will materially increase the number of people living prepared to maintain the safety of people and property from the adverse impacts
property from the adverse impacts of bushfire.                  or congregating on premises, including reconfiguring a Lot, is not located of bushfire. Post development, the proposed Lot 1 BLE will be located within a
                                                                within a medium or high bushfire hazard area.                              Potential Impact Buffer .




                                                                                                                                                                                                                                  DRAFT NOT FOR SUBMISSION PURPOSES
                                                                AO1.2
                                                                                                                                      A01.2 The proposed Lot 1 BLE has been setback a minimum of 14m from all
                                                                Development maximises setbacks from hazardous vegetation to achieve
                                                                                                                                      hazardous vegetation areas. With the implementation of the recommendations of
                                                                an acceptable risk.
                                                                                                                                      this report it is anticipated that the risk to the Lot 1 building envelope will be
                                                                                                                                      reduced to no greater than a tolerable risk thereby satisfying the SPP State Interest
                                                                Editor’s Note — PSP8 Natural Hazards provides guidance for assessing
                                                                                                                                      Policy No 2.
                                                                bushfire hazard risk and preparing a bushfire hazard management plan.

Impacts on Ecologically Important Areas
PO2                                                                                                                                        PO2
Bushfire mitigation measures do not adversely impact            No acceptable outcome provided                                             1. Bushfire mitigation measures are not expected to affect the biodiversity values
on:                                                                                                                                        currently existing within the site. A small amount of regrowth vegetation will be
                                                                                                                                           required for removal to develop the BLE and APZ requirements. This is not
           1. biodiversity values, connectivity and                                                                                        expected to affect the long term physical integrity and function of the local
              ecosystem functioning; and                                                                                                   regional ecosystem.
           2. the long term physical integrity of                                                                                          2. Bushfire mitigation measures are not expected to affect the long term physical
              waterways, wetland and areas of                                                                                              integrity of waterways, wetlands and areas of native vegetation.
              native vegetation.
Water Supply for Fire Fighting Purposes
PO3                                                    AO3.1                                                                    A03.2 – The site will not be connected to a reticulated water supply. Water
Development provides an adequate water supply for fire Premises are connected to the reticulated water supply.                  supply recommendations have been set herein consistent with SPP Assessment
fighting purpose which is reliable, safely located and                                                                          Benchmark water supply requirements.
freely accessible.                                     Editor's note—For reconfiguring a Lot, water supply needs to provide for
                                                       a minimum flow and pressure of 10 litres a second at 200kPa at all times
                                                       for fire fighting purposes.

                                                                OR

                                                                AO3.2
                                                                Where there is no available reticulated water supply, the premises has:

                                                                        1. an accessible dam, swimming pool or water tank available
                                                                           for fire fighting purposes with an onsite water volume of not
                                                                           less than 5,000 litres; and
                                                                        2. a water supply outlet pipe 50 millimetres in diameter fitted
                                                                           with a standard fire brigade fitting connected to the water
                                                                           supply (other than where the water supply is in a swimming
                                                                           pool or dam).

                                                                Editor’s Note—Water supply capacity for fire fighting purposes is in
                                                                addition to water supply capacity for other uses and activities on the
                                                                premises.




© 2020                                                                                                           26
Log in to download the original file

Appendix A - Bushfire Hazard Assessment & Management Plan.pdf · 14.0 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.