                                                                     BROWN CONSULTING (QLD) PTY LTD – SUNSHINE COAST




DIVISION 16: EXISTING SERVICES CODE

Table 14-51 Existing Services


Specific Outcomes                      Probable Solutions                     Proposed Measures
                                       (if code assessable)
Setbacks and Easements
O1 Development near a sewer,           S1.1 The footing of any structure      Due      consideration   for  all
water main, stormwater drain,          or building is located clear of the    infrastructure and existing flow
overland     flow     path    or       zone of influence but no closer        paths will occur throughout the
associated structure does not:         than 15.m (measured horizontally)      detailed design process.
(a) adversely      affect    the       from     infrastructure   including
    function of the service;           sewers,      water    mains    and
(b) place an additional load on        stormwater structures;
    the service; and                   AND
(c) unduly increase future             S1.2 No building of structure
    maintenance costs.                 overhangs the zone of influence;
                                       AND
                                       S1.3     Finished surface levels
                                       maintain a minimum of 600mm of
                                       cover, but not greater than 3m of
                                       cover     to    the  underground
                                       infrastructure;
                                       AND
                                       S1.4 If the existing surface level
                                       is altered, surface level services
                                       including      manholes       and
                                       inspection points are altered to
                                       match the new surface level;
                                       AND
                                       S1.5 Alterations are constructed
                                       in accordance with Sections 3, 4
                                       and 5 of PSP6 – Engineering
                                       Design Standards –Water and
                                       Sewerage and Section 4 of
                                       PSPs5 – Engineering Design
                                       Standards – Roads, Drainage and
                                       Earthworks;
                                       OR
                                       S1.6      Existing services are
                                       relocated and the design and
                                       construction of the relocated
                                       services is in accordance with
                                       Sections 3, 4 and 5 of PSP 6 –
                                       Engineering Design Standards –
                                       Water and Sewerage and Section
                                       4 of PSP 5 – Engineering Design
                                       Standards – Roads, Drainage and
                                       Earthworks.
O2     Maintenance access is           S2.1 A registered easement in          Due consideration will be given to
provided to all sewers, water          favour of Council is created over      the requirements of access for
mains,    stormwater     drains,       all underground infrastructure         future maintenance throughout
overland    flow   paths    and        located in private property;           the detailed design process.
associated structures.                 AND
                                       S2.2 The width of the easement
                                       is in the greater of 3m or the width
                                       of the zone of influence;
                                       AND



DEVELOPMENT APPLICATION (MCU): RSL CARE, TRADING POST ROAD, COOROY                                         PAGE   14

Used in these records

About this file

File size
354 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Engineering report [As Published].pdf · 354 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.