Skip to the record
Trusted by locals. Built for Noosa.

Council archive · source document

Engineering report [As Published] · 132007.2398

of 27

Text shows just the words. Original shows the document exactly as it was published.

                                                                     BROWN CONSULTING (QLD) PTY LTD – SUNSHINE COAST



Specific Outcomes                      Probable Solutions                     Proposed Measures
                                       (if code assessable)
                                       S9.2 Erosion and Sediment
                                       control measures are designed
                                       and implemented in accordance
                                       with the Institution of Engineers
                                       Australia (Qld Division) Soil
                                       Erosion and Sediment Control –
                                       Guidelines for Queensland
                                       Construction Sites.

O10 Sewerage Reticulation              No solution provided.                  Sewer infrastructure will be tested
infrastructure is proven to be                                                and inspected to Council’s
suitable for its use prior to                                                 satisfaction prior to hand over.
Council accepting the
dedicated asset.

O11 Sewerage Reticulation              No solution provided.                  All supporting documentation will
supply infrastructure is                                                      be provided.
provided with all supporting
technical documentation.

O12 Where buildings or other           S12.1 The footing of any building      All existing infrastructure will be
structures are in proximity to         or structure is located clear of the   protected from the proposed
Council’s water supply                 zone of influence but no closer        works.
infrastructure, provision is           than 1.5m (measured horizontally)
made to protect the                    from infrastructure including
infrastructure from physical           sewers, water mains and
damage and to allow ongoing            stormwater structures.
maintenance by Council.
                                       AND

                                       S12.2 A registered easement in
                                       favour of Council is created over
                                       all underground infrastructure
                                       located in private property;
                                       AND

                                       S12.3 The width of the easement
                                       is the greater of 3m or the width of
                                       the zone of influence;
                                       AND

                                       S12.4 The easement is centred
                                       over the centreline of the
                                       infrastructure.

O13 Alignment of sewerage              S13.1 Infrastructure is                Detailed design considerations
reticulation infrastructure is to      constructed on the preferred           will ensure ease of maintenance
allow for easy access for the          alignments in accordance with          is achieved.
ongoing maintenance by                 Section 4 of PSP 6 – Engineering
Council.                               Design Standards – Water and
                                       Sewerage.

O14 Any alterations or repairs         S14.1 Any alterations or repair to     Existing infrastructure will be
to infrastructure as a result of       infrastructure as a result of the      protected at all times. Any
the development are made at            development are completed at the       changes will be rectified at the
no cost to Council.                    developer’s expense.                   developer’s expense.




DEVELOPMENT APPLICATION (MCU): RSL CARE, TRADING POST ROAD, COOROY                                         PAGE     25

Used in these records

About this file

File size
354 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Engineering report [As Published].pdf · 354 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.