PLANNING & ENVIRONMENT COMMITTEE MEETING REPORT                              9 DECEMBER 2025


•    Bushfire Hazard Overlay Code;
•    Landslide Hazard Overlay Code; and
•    Works Codes.
The subject site is located in Doonan and is zoned Community Facilities. The proposed use is
identified as a consistent within the zone and is required to follow a code assessable application
process.
The application has been found to generally comply with all applicable statutory instruments. The
pertinent issues arising out of the assessment are discussed below:

 Criteria                  Planning Scheme              Proposal                      Complies


 Building height
 •   Metres                Max 8 metres and up to       7.962 metres and 8.82m           
                           9m metres where for the      for the pitched roof
                           pitched roof only


 Site cover                50%                          Less than 50%                    

 Gross floor area          1000m² max for individual 1,450m² (Transfer Station)          X
                           buildings
                                                     1,130m2 (Reviva Shop)

 Boundary setbacks

 Frontage                  10 metres min                37 metres                        
                                                                                         
 Side (north)              10 metres min                1000+ metres to Hollett
                                                        Road                             
                                                        180 metres to Rutch
 Side (south)              10 metres min
                                                                                         
                                                        1000+ metres to Walter
 Rear                      10 metres min
                                                        Hay Drive


 Length of wall            30 metres max                43.5 metres (Reviva Shop)        X
                                                        83.2 metres (process shed        X
                                                        and offices)

 Carparking                Sufficient spaces for        54 car parking spaces            
                           intended use




                                                                                             Page 68 of 100
Log in to download the original file

705798cff2.pdf · 41.1 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.