installed to collect vehicle dispensing spillage, blown in rain and tanker delivery
spillages.
It is recommended to engage a suitably qualified hydraulic consultant to design
the Fuel Dispensing Area (FDA), Uncovered Forecourt Area (UFA) and the tanker
unloading area hydraulic management systems. Arcadis suggests the use of a
specifically designed SPEL Puraceptor system to treat stormwater runoff in the
Fuel Dispensing Area.
Independent testing on the SPEL systems concluded the following removal
efficiencies:
97% Total Suspended Solids (TSS)
100% >5mm Gross Pollutant Solids (GP)
99.9% of light liquids (TPH) (certified discharge quality of 5ppm or less)
>30% particulate specialisation of phosphorous and nitrogen.
<0.1mg/L hydrocarbon content (minimum requirement is 10mg/L)
A risk assessment has been completed by SPEL proposing to use a
P.070.S.C1.2C Puraceptor for the site. The risk assessment has been included
in Appendix J.
The Puraceptor tank and associated infrastructure is to be installed prior to the
stormwater infrastructure discharging to Council assets.
Please do not hesitate to contact me should you have any queries regarding the above.
Yours sincerely
Larissa Hughes
Civil Engineer
(07) 3337 0887
\\hc-aus-bn-fs-01\jobs\AA007595\A-Correspondance\A0004-AA007595-AAL-01 SPEL Approval Request.docx 2
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
A0004-AA007595-AAL-01 SPEL Approval Request Letter.pdfRelated documentApplication case desk ↗
About this file
- File size
- 165 KB (small file)
- File type
No other editions are linked here.