Skip to the record
Beware of cheap imitations.

Council archive · source document

Attachment 8- Amended Engineering Report MCU12/0208

of 109

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

Very large file (61.0 MB): the whole original can take several minutes to open, especially on a phone. Text is quick to read.

Original PDF page 15, section 1. The text section number identifies this passage in the reader.

                                                                                               Engineering Report
                                                                                                 Noosa on Weyba



> An improved flood access for neighbouring properties is possible to Lake Entrance Boulevard/Aspera
  Place. This is not required for the proposed development, rather the flood free access as shown on
  SK100, is a proposed added benefit to the neighbouring community as a result of the development of the
  subject site. This existing residential area is landlocked during a Q2 event as shown on Figure 14 in the
  Cardno Flood Study accompanying this submission. Details of alignment and formation will be
  determined by Council as this access is not required by this development.
For further details refer to the Flood Study prepared by Cardno.

4.2.1          Minimum Floor Levels / Filling
Cardno Sketch SK301 indicates the pre and post development 100 year ARI inundation levels as determined
by the flood modelling.
The development west of Walter Hay Drive is predominantly outside of the 100 year ARI inundation extent.
Minor sections of filling are required within Precinct I. The 100 year ARI developed case peak flood level is
3.45 mAHD in this area. Therefore the minimum floor levels will be set above 3.95 mAHD to provide
sufficient flood immunity in accordance with SCRC requirements.
Filling is required within the Precinct F and G to ensure that sufficient flood immunity is provided. A
waterway corridor of a minimum 120 metre width will be maintained in this area. The 100 year ARI
developed case peak flood level is 2.90 mAHD in these areas. Therefore the minimum floor levels will be set
above 3.40 mAHD to provide sufficient flood immunity in accordance with SCRC requirements. The entire
area will be filled to levels above the 100 year ARI flood level (with climate change).
The proposed filling within the site will reduce available flood storage, although compared to the available
storage in Lake Weyba and the surrounding floodplain, the reduction is minimal. Flood modelling has shown
that the impact of the reduced flood storage is contained within the site.

4.2.2          Culvert Crossing
The development proposes a number of culvert crossings to provide road access, flood immunity and
stormwater detention. Cardno Sketch 300 and 302 provides indicative locations and sizing for the proposed
culvert crossings.
Where roads have been located between the Noosa Wildlife Refuge and the environmental protection, the
minimum culvert height has been set at 1200mm, with a width of 2700mm, to allow for the safe passage of
koalas and other animals.
The Department of Main Roads Fauna Sensitive Road Design (2000) indicates that culverts of this
height are recommended to allow for passage of small, medium and large mammals and semi-
arboreal mammals (which includes koalas).
The culverts have been sized to these dimensions to specifically allow the movement of fauna between
these areas.




October 2013                                        Cardno                                                      15

Used in these records

About this file

File size
61.0 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Attachment 8- Amended Engineering Report MCU12_0208.pdf · 61.0 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.