                                                                       Preliminary Acid Sulphate Soil Management Plan
                                                                                                       Noosa on Weyba




5         Borehole Analysis
Below is an overview of the testing that will be required for the detailed Acid Sulphate Soils Management
Plan.

5.1           Field Analysis – pHF and pHFOX
Field pH test (pHF) is used to identify existing acid sulphate soils by measuring the existing acidity of a
soil:water paste. A pHF of ≤4 indicates a high likelihood that acid sulphate soils are present. A pHF of > 4 and
≤ 5 indicates acid soil which will require laboratory testing. The test for pH F does not detect un-oxidised
sulphides or potential ASS.
Field pHFOX indicates the presence of iron sulphides or potential ASS. This test involves adding hydrogen
peroxide to a soil sample. Where sulphides exist, a reaction will occur.

5.2           Laboratory Analysis – Suspension Peroxide Combined Acidity and
              Sulphur (SPOCAS) Method
The SPOCAS Method is a measurement of pH, titratable acidity, sulphur and cations of two soil sub-
samples. One of these samples is oxidised with hydrogen peroxide and the other is not, this allows for the
calculation of the differences between the two samples (Ahern et al 2004).
Testing is to be undertaken for the detailed Acid Sulphate Soils Management Plan by SPOCAS or approved
equivalent such as the Chromium Reducible Sulphur Method.




10 October 2013                                      Cardno                                                       12

Used in these records

About this file

File size
61.0 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Attachment 8- Amended Engineering Report MCU12_0208.pdf · 61.0 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.