Detached House Code

bese UE Saae aN

   

Lae)
Setbacks
O7 Buildings and other
Structures are
appropriately designed
and sited to—

a) provide amenity for
users of the premises

as well as preserve the
visual and acoustic privacy
of adjoining and nearby
land uses; |

b) preserve any existing
vegetation that will

buffer the proposed
building from adjoining
uses;

C) allow for landscaping to
be provided

between buildings; and

d} maintain the visual
continuity and pattern

of buildings and

landscape elements

within the street.

SBR alternative
Provision to QDC Parts
11 and 12, P1, P2 and P7

  

 

ACCEPTABLE SOLUTIONS

 

$1.1 The minimum setback of the Detached
house or dwelling unit and associated
buildings and structures from boundaries is not
less than the minimum specified in Schedule 1;
or

$1.2 Where there is a conflict between
boundary setbacks in Schedule 1, the greater
of the setbacks prevails;

AND

$1.3 If there are no applicable setbacks shown
in Schedule 1, the siting provisions of Part 11
or 12 of the Queensland Development Code
apply.

SBR alternative provision to QDC Parts 11
and 12, A1, A2 and A7

   

COMPLIANCE

The indicated boundary
setbacks for the proposed
dwelling are as follows:

Front Setback: Om
Side NW: 1.5m
Side SE: 1.5m
Rear: 9m

Performance Solution

Required

 

Flooding and drainage
02 Buildings and other
works are designed

and sited to—

a) provide flood free
access to premises and
flood free habitable areas;
b) allow only minor, short
term and infrequent
flooding of non-habitable
areas;

c) ensure drainage does
not adversely impact upon
other premises; and

d) ensure filling or
excavation does not
adversely impact upon
other premises by—

i. causing ponding of water
on the site or nearby land;
and

ii. increasing flooding,
which adversely affects
the safety or use of any
land upstream and
downstream; and

iii, adversely affecting the

 

 

$2.1 For new buildings or structures or
additions of more than 50m2 to an existing
building or structure —floor levels of habitable
rooms are—

a) for areas where minimum floor levels are
available—not less than the specified

level;

b) for areas where flood modelling is
available—a minimum of 500mm above

the modelled flood level; and

c) for areas where flood modelling is not
available, a minimum of 500mm above

the highest known flood level;18 or

$2.2 For additions of not more than 50m2 to
an existing building or structure —floor levels
of

habitable rooms are not less than the level of
other habitable rooms in the building or
Structure;

AND

$2.3 Filling, other than accessways, does not
extend more than 1m beyond the footprint of
any building or structure, measured from outer
walls of the building or structure.

Advisory note
Council encourages building methods that

 

There are no flooding issues
pertaining to the site.

The proposal incorporates a
stepped design which
minimises the need for cut
or fill, Fil will not extend
more than 1m from the main
building line.

 

 

Used in these records

About this file

File size
7.8 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

07_0786 - MCU - Detached House [As Published].pdf · 7.8 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.