flow of water in any
overland flow path.

AND

O3 Development does not
adversely impact

on the Lake Macdonald
water supply.

avoid the use of fill such as suspended floor
construction and stepping down slopes rather
than cutting and filling.

$3.1 Buildings or other structures within the
Lake Macdonald catchment (indicated on
Figure 14-6) are located above the 98.5m AHD
level.

N/A The site is not located
within the Lake Macdonald
Catchment.

 

Electricity supply
infrastructure

O04 Uses and works
maintain an adequate
safe distance from
electrical infrastructure
including substations,
overhead powerlines,
power poles and
transformers.

$4.1 Buildings and structures (including
swimming pools, sheds, tennis courts or
outbuildings) are not constructed under
overhead electricity transmission lines, or
within electricity easements.

There are no overhead
electricity transmission lines
of electricity easements
affecting the subject
property.

 

Landslide hazard areas
O5 Detached houses,
Ancillary dwelling

units and associated uses
are sited or

constructed to maintain
the safety of people and
property from the risk of
landslide.

06 Buildings and other
structures—

a) are low rise and present
a building height
consistent with structures
on adjoining and
surrounding land;

b) have a maximum
building height of —

i) Visitor Mixed Use Zone—
3 storeys;

 

 

$5.1 If on land identified as a Landslide
Hazard

Area on Overlay Maps OM1.3-9.3, the use
does not-

a) involve the removal of vegetation other than
grass from use areas: or

b) involve excavating or filling of more than
50m3 of material (other than placement of
topsoil not exceeding 100mm in depth: or

¢) involve cut or fill with a vertical depth of
more than 1.5m relative to ground level; or
d) redirect or impede water flows in an
existing watercourse or stormwater drain;

or

€) involve construction of an on-site effluent
disposal system; or

$5.2 A site specific geo-technical report
prepared by a registered professional engineer
either--

a) certifies that the site is not at risk from
landslide emanating from the site or from
other land; or

b) identifies methods of stabilising all
buildings, accessways and use areas;

AND

$5.3 If the geo-technical report identifies
methods of stabilising buildings, accessways
and use areas, those methods are
implemented.

$6.1 The maximum number of storeys and
building height is—

a) if in the Visitor Mixed Use Zone - 3
storeys and 12m; or

b) if in the Noosa Heads Locality, Attached
Housing Zone—

i Lot 4 on SP 100064 in Serenity Close
Noosa Heads — 4 storeys and 15m;

ii otherwise - 3 storeys and 12m;

C) if in the Noosaville Locality and the
Attached Housing Zone and with frontage
to the following streets: - Russell St,

 

No vegetation will be
removed from areas
indicated as landslide

hazard. No construction or
works will take place within
the landscape hazard area.

UATE Mago 5 rm ,
Height

 

 

Used in these records

About this file

File size
7.8 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

07_0786 - MCU - Detached House [As Published].pdf · 7.8 MB (large file)