    INVESTIGATION METHODS                                    rods and the soil or casing, carrying the drill cuttings.
    The following is a_ brief summary of investigation | Only major changes in stratification can be determined
    methods currently adopted by the Company and some | from the cuttings, together with some information from
   comments on their use and application.                    "feel" and   rate  of   penetration.  More   accurate
   Test Pits - These are normally excavated with a | information on soit strata is gained by regular testing
   backhoe    or  a  tracked  excavator,  allowing   close | and sampling using the Standard Penetration Test
   examination of the insitu soils if it is safe to descend | (SPT) and undisturbed thin walled tube samples (U50).
   into the pit. The depth of penetration is limited to about | Mud Stabilized Drilling - Either Wash Boring or
   3m for a backhoe and up to 6m for an excavator. | Continuous Core Drilling can use drilling mud as a
   Limitations of test pits are the problems associated | circulating fluid to stabilize the borehole.   The term
   with disturbance and difficulty of reinstatement and the | “mud” encompasses a range of products ranging from
   consequent effects on close-by structures. Care must | bentonite to polymers such as Revert or Biogel.     The
   be taken if construction is to be carried out near test pit; mud tends to  mask    the  cuttings  and   reliable
   locations to either Properly recompact the backfill | identification is   only  possible  from   regular intact
   during construction or to design and construct the       sampling (eg. from SPT and US50 samples) or from          ©
   Structure so as not to be adversely affected by poorly | rock coring, etc.
  compacted backfill at the test pit location.              Continuous Core Drilling - A continuous core sample
  Hand Auger Drilling -     A borehole of 50 to 100mm | is obtained using a diamond or tungsten carbide
  diameter    is  advanced     by   manually    operated | tipped core barrel.    Provided full core recovery is
  equipment. Refusal of the augers can occur on a | achieved (which is not always possible in very weak
  variety of materials such as hard clay, gravel or rock | rocks and granular soils), this technique provides a
  fragments and does not necessarily indicate rock level. | very reliable method of investigation. In rocks, NMLC
  Continuous Spiral Flight Augers - The borehole is | coring (nominal 52 mm diameter) is usually used with
  advanced using 75 to 300 mm diameter continuous | Water flush. The length of core recovered is compared
  Spiral flight augers, which are withdrawn at intervals to | to the length drilled and any length not recovered is
  allow sampling or insitu testing.  This is a relatively | Shown as CORE LOSS.        The location of losses is
  economical means of drilling in clays and in sands | determined on site by the supervisor. If the location of
  above the water table.   Samples are returned to the | the loss is uncertain, it is Placed at the top end of the
 Surface by the flights or may be collected after | run, when the core is Placed in a storage tray and
 withdrawal of the augers. Information from the drilling | fecorded on the tog.                                       ©
 (as distinct from specific sampling) is of relatively lower | Standard Penetration Tests - Standard Penetration
 reliability due to remouiding, inclusion of cuttings from | Tests (SPT) are used mainly in non-cohesive soils, but
 above or softening of samples by groundwater, or | can also be used in cohesive soils, as a means of
 uncertainties as to the original depth of the samples. | indicating density or Strength. The test procedure is
 Augering below the groundwater table has a lower         described in Australian Standard 1289, "Methods of
 reliability than augering above the water table. Various | Testing Soils for Engineering Purposes” - Test 6.3.1.
 drill bits are attached to the base of the augers during | The test is carried out in a borehole by driving a 50mm
 the drilling. The depth of refusal of the different bit | diameter split sample tube with a tapered shoe, under
 types can provide information as to the Strength of the | the impact of a 63 kg hammer with a free fall of 760
 material encountered. Generally two different bit types | mm.  It is normal for the tube to be driven in three
are used. The V' bit is a V shaped steel bit and the | successive 150 mm increments and the 'N’ value is
'TC' bit is a tungsten carbide tipped screw type bit.    taken as the number of blows for the fast 300 mm, the
Wash Boring - The borehole is usually advanced by a | upper      150 mm_ being     neglected due    to possible
rotary bit with water or fluid pumped down the hollow } disturbance from the drilling method. In dense sands,
drill rods and returned up in the space between the | very hard clays or weak rock, the full 450 mm
NOTEREP.SAM                                                                 SOIL SURVEYS ENGINEERING

Used in these records

About this file

File size
4.1 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

0015584F.001.pdf · 4.1 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.