Council archive · source document
Extension to Currency Period - Approved REC14 0005 04 {As Published} · REC14/0005.04
ENGINEERING
External Works
7. Gateway Drive must be upgraded for the length of its frontage to the subject site. The
works must be undertaken in accordance with an Operational Works approval and must
include in particular the construction of a pedestrian footpath in accordance with the
conditions of this Decision Notice. This condition is imposed pursuant to s665 of the
Sustainable Planning Act 2009 being non-trunk infrastructure.
Pedestrian and Bicycle Facilities
8. Pedestrian and bicycle facilities must be provided for the development. The works must
be undertaken in accordance with an Operational Works approval and must include in
particular a 2 metre wide footpath within the road verge extending from the end of the
existing pathway in Gateway Drive to the northern boundary of proposed Lot 103. This
condition is imposed pursuant to s665 of the Sustainable Planning Act 2009 being non-
trunk infrastructure.
Stormwater Drainage
9. The site must be provided with a stormwater drainage system connecting to a lawful
point of discharge. The works must be undertaken in accordance with an Operational
Works approval and must include in particular:
(a) A connection point for the future development of proposed Lot 103 to the existing
stormwater drainage system
(b) The retention of the existing overland flowpath that conveys stormwater runoff
from the adjoining property (Lot 26 SP151406) through proposed Lot 103. The
flows must be contained and conveyed wholly within a combined drainage solution
consisting of underground drainage, capable of accommodating flows up to a Q10
event, and a landscaped and suitably stabilised (rock lined or other engineered
alternative) open drain. The design of the drain must be sufficient to include all
design storm events up to and including the 1%AEP event of critical duration.
Design calculations (that include at a minimum depth of flow and velocity) and
certification by a suitably qualified RPEQ demonstrating the above must be
submitted as part of the operational works application
(c) Additional elements in the design of the open drain (localised bunding etc) that
allows stormwater flows from the minor storm event to enter the existing piped
system and ensure that velocities (generated in both the major and minor events)
are in accordance with the safety guidelines recommended in QUDM.
Electricity and Telecommunication Services
10. Underground reticulated electricity and telecommunication services must be provided to
each lot in accordance with an approval for Operational Works and the standards and
requirements of the relevant service provider.
11. Unless otherwise stipulated by telecommunications legislation at the time of
construction, the development must be provided with all necessary conduits, pits and
pipes to accommodate the future connection of optic fibre technology
telecommunications.
12. Certification must be submitted to Council from all relevant service providers which
certifies that the development has met the requirements of this Decision Notice and all
applicable legislation at the time of construction.
Easements
13. A drainage easement must be created within proposed Lot 103. The easement must be:
Document Set ID: 23331562
Version: 4, Version Date: 04/11/2024 Page 3 of 8
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Extension to Currency Period - Approved REC14 0005 04 {As Published}Related documentApplication case desk ↗
About this file
- File size
- 195 KB (small file)
- File type
No other editions are linked here.