LIVABLE HOUSING                                                                                           NCC - LIVABLE HOUSING GUIDELINES SHEET
                                                                                                                                  NCC 2022 COMMENCING 18th OCTOBER 2023 FOR HOUSING
PART 1 - DWELLING ACCESS
A STEP-FREE ACCESS PATH IS REQUIRED TO THE HOUSE FROM THE ALLOTMENT BOUNDARY TO                                            PART 4 - COMPARTMENT                                                                                     PART 6 - REINFORCEMENT OF BATHROOM AND SANITARY COMPARTMENT
THE ENTRANCE DOOR.                                                                                                         AT LEAST ONE SANITARY COMPARTMENT TO BE LOCATED ON THE                                                   - REQUIRED TO:
- CAN BE PROVIDED VIA AN ATTACHED GARAGE/CARPORT IF IT PROVIDES STEP-FREE INTERNAL                                         GROUND FLOOR / ENTRY LEVEL (I.E A ROOM CONTAINING A TOILET).                                             (A) THE NOMINATED SANITARY COMPARTMENT IN PART 4;
ACCESS TO THE HOUSE (MIN. SPACE SIZE IS 5.4m x 3.2m).                                                                      - THE SANITARY COMPARTMENT MUST HAVE 1200mm x 900mm                                                      (B) A BATHROOM CONTAINING THE NOMINATED SHOWER IN PART 5;
- CAN ALSO BE PROVIDED FROM ANOTHER CAR PARKING SPACE ON SITE (5.4m x 3.2m).                                               CIRCULATION SPACE IN FRONT OF THE PAN, WITH NO OBSTRUCTION                                               (C) A BATHROOM WITH A BATH (NOT FREESTANDING) WHICH ALSO CONTAINS THE
- NOT REQUIRED IF THERE IS NO ATTACHED GARAGE/CARPORT PROVIDED AND THE FRONT ACCESS                                        WITHIN 450mm OF THE CENTRE OF THE PAN.                                                                   SHOWER NOMINATED IN PART 5.
IS STEEPER THAN 1:14, OR THE DIFFERENCE IN LEVEL BETWEEN THE FRONT DOOR AND THE FRONT                                      - A DOOR CANNOT SWING INTO THIS CIRCULATION SPACE.                                                       - IF A TOILET PAN IS MORE THAN 460mm FROM A SIDE WALL, NO SHEETING IS
BOUNDARY IS, OR IF THERE IS NOT ENOUGH SPACE TO CONSTRUCT A RAMP.                                                          - ARCHITRAVES, SKIRTINGS, TOILET ROLL HOLDERS, DOOR STOP, AND                                            REQUIRED/
- IF A RAMP IS REQUIRED, THERE ARE GRADIENTS, LENGTHS AND WIDTHS SPECIFIED.                                                THE LIKE CAN BE WITHIN THE CIRCULATION SPACE.                                                            - REINFORCING TO BE:
                                                                                                                                                                                                                                    (A) TIMBER NOGGING, MIN. 25mm THICK; OR
PART 2 - DWELLING ENTRANCE                                                                                                 PART 5 - SHOWER                                                                                          (B) MIN. 12mm STRUCTURAL PLYWOOD; OR
- CAN BE PROVIDED VIA GARAGE INTERNAL DOOR WITH NO STEP.                                                                   AT LEAST ONE SHOWER MUST HAVE A HOBLESS AND STEP-FREE ENTRY.                                             (C) LIGHT GAUGE STEEL FRAMING \ METAL PLATES.
- TYPICALLY A 870mm WIDE DOOR LEAF REQUIRED.                                                                               - THE SHOWER DOES NOT HAVE TO BE ON THE GROUND / ENTRY LEVEL.                                            - REINFORCING REQUIREMENTS:
                                                                                                                           - A MAX. 5mm LIP MAY BE PROVIDED FOR WATER RETENTION PURPOSES.                                           (A) BATH NOGGING: (NOTE: LOCATIONS ARE DIFFERENT IF PLY SHEETING IS USED)
OPTIONS IF THE FRONT DOOR IS TO BE THE STEP-FREE ENTRANCE:                                                                 - THERE ARE QUEENSLAND-SPECIFIC VARIATIONS (AS PER QDC MP4.5) TO WATER=PROOFING
(A) LEVEL THRESHOLD:                  (B) MAX. 5mm ROUNDED/BEVELED SILL:                                                   REQUIREMENTS, WHICH ALLOW FOR ALTERNATIVE CONSTRUCTION DETAILS TO ACHIEVE A "STEP-FREE"
                                                                                                                           SHOWER ENTRY WHILE STILL BEING DEEMED AN ENCLOSED SHOWER INCLUDING:

                                                                                                                           (A) A SHOWER WITHOUT A STEP DOWN OR A LINEAR DRAIN ACROSS THE ENTRY. WITH A WATER BAR
                                                                                                                           INSTALLED ACROSS THE OPENING WITH A MAX. HEIGHT OF 5mm.




(C) THRESHOLD RAMP IN DOOR JAMB (1:8):                                   (D) THRESHOLD WITH NO LIP OR UPSTAND GREATER
                                                                         THAN 15mm WITHIN THE SILL PROFILE. MAX 5mm
                                                                         HEIGHT DIFFERENCE WITH ADJOINING FINISHED
                                                                         FLOOR SURFACE LEVELS:




                                                                                                                           (B) A SHOWER WITH A MAXIMUM LIP OF 5mm AT THE ENTRY, AND A SHOWER SCREEN WITH A DEFLECTOR.

- WEATHERPROOFING REQUIRED IF THE FRONT DOOR IS TO BE THE LEVEL THRESHOLD ENTRANCE:
(A) CHANNEL DRAIN IN FRONT OF DOOR SILL: OR
(B) DECKING ON OUTSIDE OF DOOR WITH DRAINAGE UNDER: OR
(C) 1200mm x 1200mm ROOF ABOVE THE FRONT ENTRY DOOR
- IF THE FRONT DOOR IS TO BE THE LEVEL THRESHOLD ENTRANCE, A MIN. 1200mm x 1200mm LANDING
  IS REQUIRED OUTSIDE THE FRONT DOOR.

PART 3 - INTERNAL DOORS AND CORRIDORS
820mm CLEAR OPENING WIDTH AND A LEVEL THRESHOLD (INCLUDING A MAX. 5mm ROUND/BEVELED
LIP, OR MAX 1:8 DOOR SILL) ARE REQUIRED TO INTERNAL DOORS LEADING TO:                       (C) A SHOWER WITH A LINEAR DRAIN AT THE ENTRY TO THE SHOWER
(A) ANY HABITABLE ROOMS ON THE GROUND FLOOR/ENTRY LEVEL;
(B) LAUNDRY, IF LOCATED ON THE GROUND FLOOR/ENTRY LEVEL;
(C) SANITARY COMPARTMENT ON THE GROUND FLOOR/ENTRY LEVEL;
(D) THE ROOM CONTAINING THE STEP-FREE SHOWER (GROUND OR UPPER FLOOR, DEPENDING ON
WHERE IT IS LOCATED);
(E) ATTACHED GARAGE (IF PROVIDING THE REQUIRED ACCESS PATH);
- INTERNAL CORRIDORS / HALLWAYS LEADING TO THE ABOVE DOORS, MUST BE AT LEAST 1000mm WIDE
(NOT INCLUDING SKIRTING, ARCHITRAVES, ETC.). IF THE STEP-FREE SHOWER IS ON THE UPPER FLOOR,
THE UPPER FLOOR CORRIDOR WOULD NEED TO BE 1000mm WIDE.

                                                                                                                                                                Project Description
                                                                                          No.                   Description                          Date       PROPOSED DWELLING                                                   HOUSING PROVISIONS
                                             W: www.theshedhouse.com.au                   A     DESIGN ROUND 1 - ISSUE A                           07.11.2025
                                                                                                                                                                                                                                      Project number                              TSH25038
                                                                                          B     DESIGN ROUND 2 - ISSUE B                           12.11.2025
                                                                                                                                                                                                                                                                                                        WD.127
                                                                                                                                                                Project Address
                                                                                          C     RELEASED FOR APPROVAL                              08.12.2025                                                                         Date                                       15.02.2026                                               27 of 33
                                             ABN: 39 630 500 695                                                                                                9 RULES ROAD, POMONA QLD 4568
                                                                                          D     RELEASED FOR APPROVAL                              05.02.2026                                                                         Drawn by                                              AG                                          Sheets in Set
                                             QBCC: 1514 0876                              E     RELEASED FOR APPROVAL                              15.02.2026
                                                                                                                                                                Client Name                       Client                              Checked by                                 TSH TEAM            Scale
                                                                                                                                                                                                                C_I      C_2_I
                                                                                                                                                                BARNES                           Approval                             Soil Class: TBC                                                Wind Design: TBC
 Do not scale off this drawing. All dimesnions to be verified on site.                                                                                                                           Barnward Construction Services Pty Ltd owns copyright in this drawing. Unauthorised use, reproduction, or any adaptation is forbidden & will be prosecuted.
Log in to download the original file

REVISED DESIGN - 9 Rules Road - Design Plans - Rev E - 15022026.pdf · 4.1 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.