REVISED DESIGN - 9 Rules Road - Design Plans - Rev E - 15022026
Plans and drawings: the text below has words only, no drawings.
ELECTRICAL & GAS LEGEND
SINGLE GPO AT 1050 SERVICES AND CONNECTIONS
DOUBLE GPO AT 300
DOUBLE GPO + USB POINT AT 300
USB EXHAUST VENTING
DOUBLE GPO AT 1050, LAUNDRY DOUBLE GPO
HEIGHT IS DICTATED BY PIPE LOCATIONS MAIN BATHROOM AND WC
DOUBLE GPO + USB POINT AT 1050, LAUNDRY DOUBLE USB
GPO HEIGHT IS DICTATED BY PIPE LOCATIONS
CEILING MOUNTED + VENTED OUT WALL OR EAVES
SINGLE GPO (FRIDGE) AT 1800 (DESIGN WILL DETERMINE IF EAVE OR WALL VENTILATION)
SINGLE GPO (DISHWASHER AND MICROWAVE) AT 650
SINGLE GPO (GARAGE) TO CEILING FOR AUTOMATIC
WALL MOUNTED VENTED OUT WALL
HWS
DOOR, SET MIN. 3.0m BACK FROM DOOR W (EXTERNAL WALLS ONLY)
W
WEATHERPROOF DOUBLE GPO sensor sensor
HOT PLATES ( ELECTRIC / GAS ) REFER SPECIFICATION. HP CONNECTIONS
WITH SINGLE GPO OVER FOR RANGEHOOD
UNDER BENCH OVEN ( ELECTRIC / GAS )
REFER SPECIFICATION. UBO DOES THE SITE HAVE AN EXISTING YES NO
GAS BAYONET FOR B.B.Q./HEATER WHERE SPECIFIED.
POWER CONNECTION
1000
TELEPHONE OUTLET
DATA DISTANCE TO POWER CONNECTION
COMPUTER / DATA OUTLET
TV
950
TELEVISION OUTLET AT 400
TSH TO ORGANISE CONSTRUCTION POWER BOX YES NO
EXHAUST FAN
CLIENT TO ORGANISE CONSTRUCTION BOX YES NO
CEILING FAN AS SPECIFIED
1500
IS THE DWELLING TO BE CONNECTED TO AN YES NO
CEILING FAN WITH LIGHT
OFF-GRID SYSTEM
EXHAUST FAN & LIGHT COMBO.
TSH TO ORGANISE SITE GENERATOR YES NO
DOUBLE FLUORESCENT (GARAGE)
1000 1250 2000
SINGLE FLUORESCENT
CLIENT TO ORGANISE SITE GENERATOR YES NO
CIRCULAR FLUORESCENT (REFER SPECIFICATION)
SELECTED DOWNLIGHT NO TV ARIEL TO BE PROVIDED
SELECTED LED DOWNLIGHT 1800
DATA
LV
SELECTED LOW VOLTAGE DOWNLIGHT
PLEASE NOTE: WASTE WATER POWER CONNECTION (IF APPLICABLE)
SELECTED BUNKER
AND MAINS POWER CONNECTION WILL BE BILLED DIRECTLY TO THE
HALF OYSTER LIGHT (STAIR CASE) OWNER BY OUR CHOSEN ELECTRICIAN, UNLESS OTHERWISE STATED.
SELECTED PARAFLOOD
1000
LED STEP LIGHT
1000
SELECTED EXTERNAL WALL LIGHT
1000 DATA
LED STRIP LIGHT TO NICHE sensor
W W
SMOKE DETECTOR
SELECT SKYLIGHT
HOT WATER SYSTEM
METER BOX ( ELECTRICAL )
METER BOX ( GAS ), TO BE INSTALLED ONLY WHERE
SPECIFIED. REFER SPECIFICATION.
NBN EXTERNAL 'PCD' BOX AND INTERNAL EQUIPMENT
INSTALLATION. REFER NBN INSTALLATION GUIDE.
INSTANTANEOUS GAS HOT WATER SYSTEM
LIGHTS SWITCHED ONE WAY
(REFERS TO ACTUAL NUMBER OF LIGHTS SWITCHED)
WALL PLATE, 1050 ABOVE F.F.L.
LIGHTS SWITCHED TWO WAY
(REFERS TO ACTUAL NUMBER OF LIGHTS SWITCHED)
WALL PLATE, 1050 ABOVE F.F.L.
LIGHTS SWITCHED THREE WAY
(REFERS TO ACTUAL NUMBER OF LIGHTS SWITCHED)
WALL PLATE, 1050 ABOVE F.F.L.
N O T E :ELECTRIC METERBOARD, HOT WATER SYSTEM / BOOSTER & GAS
METERBOARD, WHERE REQUIRED, SHALL BE LOCATED AND POSITIONED
ON-SITE, RELATIVE TO THE POSITION OF THE INCOMING POWER AND
SUPPLY GAS LINES. REFER SPECIFICATION.
Project Description
No. Description Date PROPOSED DWELLING ELECTRICAL PLAN
W: www.theshedhouse.com.au A DESIGN ROUND 1 - ISSUE A 07.11.2025
Project number TSH25038
B DESIGN ROUND 2 - ISSUE B 12.11.2025
WD.129
Project Address
C RELEASED FOR APPROVAL 08.12.2025 Date 15.02.2026 29 of 33
ABN: 39 630 500 695 9 RULES ROAD, POMONA QLD 4568
D RELEASED FOR APPROVAL 05.02.2026 Drawn by AG Sheets in Set
QBCC: 1514 0876 E RELEASED FOR APPROVAL 15.02.2026
Client Name Client Checked by TSH TEAM Scale As indicated
C_I C_2_I
BARNES Approval Soil Class: TBC Wind Design: TBC
Do not scale off this drawing. All dimesnions to be verified on site. Barnward Construction Services Pty Ltd owns copyright in this drawing. Unauthorised use, reproduction, or any adaptation is forbidden & will be prosecuted.