Council archive · source document
Attachment B - Proposed Plans · MCU19/0049.01
Plans and drawings: the text below has words only, no drawings.
FH-10-003
69
m
1
FH
66m
FH2
FH2
INSTALL A NEW
FH2 BALCONY GATE.
FH1
FH1
FH2
FH2
FH1
62
FH1
m
60
m
FH2
1
FH FH1 FH1
FH1
FH-10-003
FH1
FH1
66
m
FH1
FH2
FH1
FH1 FH1
69.7
FH1 m
FH2
FH2
FH1
FH1
FH2
1
FH
FH2
FH1
FH1
1 FH1
1 FH
FH
69.5
m
H2
1
FH
1
FH2F
FH
m
53 DPH
FH1 FH1 FH1 FH1 FH1 21.6m
FH-10-001
DPH FH
1
FH1
FH1
10
100
0
FH1
FH FH1
1
100 100 FH1
H eCW eCW eCW eCW eCW eCW eCW eCW eCW eCW eCW eCW eCW H
FH1
FH1
eCW FH
SUPPLY & INSTALL A DOUBLE PILLAR SUPPLY & INSTALL A NEW DOUBLE PILLAR 1
HYDRANT TO BE INSTALLED NOT LESS THAN HYDRANT WITH A 4000mm WIDE x 3000mm eCW
10m FROM BUILDING HIGH 90/90/90 RATED FIRE WALL DIRECTLY eCW
BEHIND THE HYDRANT. REFER TO DETAIL. eCW FH1
APPROXIMATE LOCATION OF EXISTING TREE. 100
APPROXIMATE LOCATION OF EXISTING PROPOSED PUMPSET IS TO BE INSTALLED eCW
H 28.3m FH
AUTHORITY WATER MAIN. CLEAR OF TREE ROOT NETWORK. -10
-00
1
SUPPLY & INSTALL AN ALINE PREPACKAGED SINGLE eC
W
DIESEL FIRE HYDRANT PUMPSET WITHIN
ENCLOSURE. PUMP TO BE INSTALLED A MINIMUM OF eC
6m AWAY FROM ALL PARTS OF THE BUILDING. W
PUMP DUTY TO BE [email protected] ENCLOSURE 1200mm WIDE X 3600mm eC
W
LONG. PUMPSET TO BE LOCATED IN FIRST CARPARK.
SUPPLY & INSTALL A NEW 100mm FIRE
HYDRANT BOOSTER ASSEMBLY WITH A
100mm DOUBLE DETECTOR CHECK VALVE
WITH A 20mm BYPASS. BOOSTER TO BE
INSTALLED A MINIMUM OF 10m AWAY FROM
ALL PARTS OF THE BUILDING.
PLUMBING CONTRACTOR IS TO PROVIDE A
NEW 100mm CONNECTION TO THE
AUTHORITY'S WATER MAIN FOR FIRE WATER
SUPPLY.
MECHANICAL ELECTRICAL HYDRAULIC FIRE ENERGY NABERS STORMWATER SECTION J BEEC
This drawing is not to be used for any construction purpose unless noted Project Drawing Title Discipline Scale 1:200 @ A1
otherwise in the issue column. Marline Newcastle pty ltd. accept no responsibility
EDEN PRIVATE HOSPITAL GROUND FLOOR
for any unauthorised use of drawings issued on a "information and discussion"
only basis. A 13.04.26 FOR CONSTRUCTION ZM CB DW
50 MAPLE STREET, COOROY QUEENSLAND FIRE HYDRANT LAYOUT FIRE HYDRANT SERVICES
N
This drawing is copyright and is the property of Marline Newcastle pty ltd and must
2 27.01.26 REVISED AS REQUESTED ZM CB
not be retained, copied or used without written consent of marline newcastle. Job No. Drawing No. Rev
1 16.12.25 100% ISSUE FOR REVIEW ZM CB
[email protected] www.marline.com.au (02) 4925 9300 0 25mm
50mm 100mm ON A1 ORIGINAL
Rev Date Reason for Issue Drawn Design Verify MN16443 FH-10-002 A
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Attachment B - Proposed Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 518 KB (small file)
- File type
No other editions are linked here.