length of 5 metres (Refer Figure
9.4.9.3C).
AO13.5
For “Y” and “T” shaped jetty heads—
(a) a maximum area 10.5m²
excluding any walkway is
provided; and
(b) a walkway with a minimum
length of 3 metres is
provided (Refer Figure
9.4.9.3D).
AO13.6
Gangways and walkways serving
jetties and pontoons have at least
one rigid handrail fitted and meet
the following—
(a) for dwelling houses – a
minimum width of 750
millimetres and a maximum
width of 1.5 metres;
(b) for other residential uses –
(i) the gangway for a single
berth pontoon has a
minimum width of 900
millimetres;
(ii) the gangway for a multiple
berth pontoon has a
minimum width of 1.2
metres if fitted with one
handrail and 900 millimetres
if fitted with a handrail on
each side;