Log in to see the plans as drawn MCU to establish Entertainment & Dining Business – Type 2 (Gym)
2/37 Gateway Drive, Noosaville
APPENDIX A
Architectural Plans & Illustrations
MATERIAL CHANGE OF USE TO ESTABLISH
ENTERTAINMENT & DINING BUSINESS – TYPE 2
RECREATION, AMUSEMENT & FITNESS
Unit 2/37 GATEWAY DRIVE, NOOSAVILLE described as
Lot 2 on SP1777640
Applicant: Leigh Stalker T/A Noosa Strength Centre
Prepared By: Zest Building Design
Date: 14 September 2017
23
GAT VER 1 140917
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLarge file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 2 pages
Page 2
REAL PROPERTY DESCRIPTION
Lot: 2 On: 177640
Lot / Site Area (m²): 0 m²
Local Government: Noosa Shire Council
STATUTORY INFORMATION:
Building Classification: 6
Storeys: 1
N
Climate Zone: 2
Wind Category: N3
General
Do not scale from these drawings, figured dimensions take
precedence at all times - when in doubt consult the designer
prior to commencing construction. It is the builders
responsibility to:
• Verify all dimensions and levels on site.
• Ensure all boundary setbacks are strictly adhered to.
• Verify location and levels of all services on site.
• Verify that floors and finished levels enable connection to
required services on site.
• Real property information to be confirmed by licensed
surveyor prior to construction.
• Bearings have been corrected by modelling software to read
in a clockwise direction. This may cause discrepancies of 180
deg from original survey information.
GATEWAY DRIVE
• Site levels, driveway design & site works to detail by others.
These drawings have been prepared for building permit
application only. It is the builder's / proprietor's responsibility
to further interpret the design and drawings to detail the
project for construction.
Termites
Protection against subterranean termites to be in accordance
with A.S. 3660 Part 1. (protection of buildings from
subterranean termites). Protection against subterranean
termites to apply to all "primary building elements". The
builder is to provide physical barriers to
the entry by subterranean termites by construction of all
slabs & timber floor framing in accordance with A.S. 2870.1
(Residential footing and slab construction). and A.S. 3600
(Concrete structures code). In addition all slab penetrations
are to be protected using stainless steel mesh. (Termimesh or
equivalent fitted to manuf. spec.). External perimeter barrier
to be installed by excavation trenches, treating the exposed
trench and backfilling the trench with treated material and
protecting the trench with a 50mm thick concrete cover strip
x 300mm wide measured from the external wall of the
building. 2 durable notices shall be installed in prominent
locations stating method of protection, date of installation,
life expectancy and scope and duration of future inspections.
Regular inspections of the building are to be carried out to
ensure the barrier has not been bridged by termites.
Inspections are to be carried out as per notices.
Drawing Schedule
Current Revision
SITE PLAN Sheet No. Sheet Name Revision Date
A.01 SITE PLAN 1 30/08/2017
Scale 1 : 200
A.02 PROPOSED FLOOR PLAN 1 30/08/2017
MCU FITNESS CENTRE SCALE @A3
0 1m 2m 3m 4m 5m
ZEST BUILDING DESIGN STUDIO Project Address Drawing Title 1:100
Sunshine Coast 2/37 Gateway drive, Noosaville
P | 0457314346
A | 30 Wattlebird Drive, Doonan, QLD 4562
E | [email protected]
W | www.zestbuildingdesign.com.au
ABN: 37 601 151 508
Q.B.C.C Lic. No: 1307012
QLD
Client Name
SITE PLAN
A.01
Phase Bld # Issue
Designer (s)
I. Brundell
RG STRATEGIC 1
Issue
MCU Application
Description
30/08/2017
Date
17077 CA 1
Original sheet size A3 (297x420) Plot date: 06-Sep-17 2:59:11 PM
MCU
Page 3
SMOKE DETECTORS PROTECTION OF OPENABLE WINDOWS
To comply with AS 3786-2014 and the
GATEWAY DRIVE
Protection of openable windows to be in compliance
Building Fire Safety (Domestic Smoke
with Part 3.9.2.5, Vol 2 of the NCC. A window opening
Alarms) Legislation Amendment 200 6000 200
must be provided with protection, if the floor below the
Regulation 2016 - smoke alarms. window in a bedroom is 2m or more above the surface
Approved smoke detectors with mains beneath (Unless the lowest level of the window opening
supplied power and battery backup. is more than 1.7m above the finished floor level).
Smoke alarms must be installed on each
storey:
200
i) in each bedroom; and NOTES:
ii) in hallways which connect bedrooms
and the rest of the All plumbing fixtures and installations including
dwelling; or pressure limiting devices, hot water systems and dual
flush toilet suites to be WELS rated in accordance with
3000
iii) if there is no hallway, between the
bedrooms and other parts MEZZANINE AS/NZ 6400 - 2005 & AS 3500, and incompliance with
of the storey; and Part 4.1 of the Queensland Development Code (QDC).
iv) if there are no bedrooms on a storey
at least one smoke alarm All wet areas are to be waterproofed in accordance
must be installed in the most likely path with Clause 3.8.1, Vol 2 of NCC.
of travel to exit the
dwelling. All glazing is to be installed in accordance with Clause
Where practicable smoke alarms must 3.6, Vol 2 of the NCC.
be placed on the ceiling. Smoke alarms
must not be placed: Stairways are to be installed in accordance with Clause
i) within 300mm of a corner of a ceiling 3.9.1, Vol 2 of the NCC.
and a wall;
ii) within 300mm of a light fitting; Handrails and balustrades are to be installed to comply
iii) within 400mm of an air-conditioning with Clause 3.9.2, Vol 2 of the NCC.
vent;
iv) within 400mm of the blades of a Masonry to comply with AS 3700.
ceiling fan. External fixtures & fittings to be non-combustible & hot
14700
dip galvanised or of corrision resitant material.
9110
Confirm all dimensions and design information on site
Gross Building Area prior to commencement of work.
Name Area (m²) Squares (SQ)
FLOOR 77.3 m² 8.3
MEZZANINE 12.5 m² 1.3
Total Use Area 89.8 m² 9.7
STORE
90
2500
WC
200
3910 90 1010 90 900
PROPOSED FLOOR PLAN
Scale 1 : 100
MCU FITNESS CENTRE SCALE @A3
0 1m 2m 3m 4m 5m
ZEST BUILDING DESIGN STUDIO Project Address Drawing Title 1:100
Sunshine Coast 2/37 Gateway drive, Noosaville
P | 0457314346
A | 30 Wattlebird Drive, Doonan, QLD 4562
E | [email protected]
W | www.zestbuildingdesign.com.au
ABN: 37 601 151 508
Q.B.C.C Lic. No: 1307012
QLD
Client Name
PROPOSED FLOOR PLAN
A.02
Phase Bld # Issue
Designer (s)
I. Brundell
RG STRATEGIC 1
Issue
MCU Application
Description
30/08/2017
Date
17077 CA 1
Original sheet size A3 (297x420) Plot date: 06-Sep-17 2:59:12 PM
MCU