Original source · versioned page text
Appendix A - Architechual Plans - 2 - 37 Gateway Drive Noosaville - 14.09.17
Attached to the e-mail MCU - Gym - MCU17/0524.
Plans and drawings
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn REAL PROPERTY DESCRIPTION
Lot: 2 On: 177640
Lot / Site Area (m²): 0 m²
Local Government: Noosa Shire Council
STATUTORY INFORMATION:
Building Classification: 6
Storeys: 1
N
Climate Zone: 2
Wind Category: N3
General
Do not scale from these drawings, figured dimensions take
precedence at all times - when in doubt consult the designer
prior to commencing construction. It is the builders
responsibility to:
• Verify all dimensions and levels on site.
• Ensure all boundary setbacks are strictly adhered to.
• Verify location and levels of all services on site.
• Verify that floors and finished levels enable connection to
required services on site.
• Real property information to be confirmed by licensed
surveyor prior to construction.
• Bearings have been corrected by modelling software to read
in a clockwise direction. This may cause discrepancies of 180
deg from original survey information.
GATEWAY DRIVE
• Site levels, driveway design & site works to detail by others.
These drawings have been prepared for building permit
application only. It is the builder's / proprietor's responsibility
to further interpret the design and drawings to detail the
project for construction.
Termites
Protection against subterranean termites to be in accordance
with A.S. 3660 Part 1. (protection of buildings from
subterranean termites). Protection against subterranean
termites to apply to all "primary building elements". The
builder is to provide physical barriers to
the entry by subterranean termites by construction of all
slabs & timber floor framing in accordance with A.S. 2870.1
(Residential footing and slab construction). and A.S. 3600
(Concrete structures code). In addition all slab penetrations
are to be protected using stainless steel mesh. (Termimesh or
equivalent fitted to manuf. spec.). External perimeter barrier
to be installed by excavation trenches, treating the exposed
trench and backfilling the trench with treated material and
protecting the trench with a 50mm thick concrete cover strip
x 300mm wide measured from the external wall of the
building. 2 durable notices shall be installed in prominent
locations stating method of protection, date of installation,
life expectancy and scope and duration of future inspections.
Regular inspections of the building are to be carried out to
ensure the barrier has not been bridged by termites.
Inspections are to be carried out as per notices.
Drawing Schedule
Current Revision
SITE PLAN Sheet No. Sheet Name Revision Date
A.01 SITE PLAN 1 30/08/2017
Scale 1 : 200
A.02 PROPOSED FLOOR PLAN 1 30/08/2017
MCU FITNESS CENTRE SCALE @A3
0 1m 2m 3m 4m 5m
ZEST BUILDING DESIGN STUDIO Project Address Drawing Title 1:100
Sunshine Coast 2/37 Gateway drive, Noosaville
P | 0457314346
A | 30 Wattlebird Drive, Doonan, QLD 4562
E | [email protected]
W | www.zestbuildingdesign.com.au
ABN: 37 601 151 508
Q.B.C.C Lic. No: 1307012
QLD
Client Name
SITE PLAN
A.01
Phase Bld # Issue
Designer (s)
I. Brundell
RG STRATEGIC 1
Issue
MCU Application
Description
30/08/2017
Date
17077 CA 1
Original sheet size A3 (297x420) Plot date: 06-Sep-17 2:59:11 PM
MCU
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.